2005
DOI: 10.1016/j.corsci.2005.05.034
|View full text |Cite
|
Sign up to set email alerts
|

Thermodynamic characterization of metal dissolution and inhibitor adsorption processes in mild steel/2,5-bis(n-thienyl)-1,3,4-thiadiazoles/hydrochloric acid system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

13
307
0
1

Year Published

2008
2008
2024
2024

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 915 publications
(321 citation statements)
references
References 31 publications
13
307
0
1
Order By: Relevance
“…In order to gain more information about the mode of adsorption (physisorption, chemisorption or comprehensive adsorption) of the drug on the surface of CS, the experimental data have been tested with several adsorption isotherms (Langmuir, Freundlich, Temkin, kinetic-thermodynamic model and Flory-Huggins isotherm). A very good fit is observed with a regression coefficient (R 2 = 0.9994) for the Langmuir adsorption isotherm which confirms the validity of this approach (29). The Langmuir adsorption isotherm is based on the view that every adsorption site is identical and energetically equivalent (30).…”
Section: Adsorption Considerationsupporting
confidence: 54%
“…In order to gain more information about the mode of adsorption (physisorption, chemisorption or comprehensive adsorption) of the drug on the surface of CS, the experimental data have been tested with several adsorption isotherms (Langmuir, Freundlich, Temkin, kinetic-thermodynamic model and Flory-Huggins isotherm). A very good fit is observed with a regression coefficient (R 2 = 0.9994) for the Langmuir adsorption isotherm which confirms the validity of this approach (29). The Langmuir adsorption isotherm is based on the view that every adsorption site is identical and energetically equivalent (30).…”
Section: Adsorption Considerationsupporting
confidence: 54%
“…R p value decreases with the increasing temperature due to the desorption process from the mild steel surface to the bulk of the solution. The obtained semicircles are not perfect semicircles; this is because of the typical behavior of a solid metal electrode that shows frequency dispersion of the impedance data [10,11] which is attributed to the roughness and other inhomogeneities of the solid surface [12][13][14].…”
Section: Electrochemical Impedance Spectroscopic (Eis) Measurementmentioning
confidence: 99%
“…It was found that the linear correlation coefficients clearly prove that the adsorption of the formazan of benzaldehyde (FB) from 1 M HCl than 2 M HCl solutions on the mild steel corrosion obeys the Langmuir adsorption isotherm. The negative values of ∆G 0 ads for the addition of inhibitors indicate that the process of adsorption of studied inhibitors is spontaneous in nature 21 . The free energy of adsorption of (∆G ads ), in 1 M HCl was found to be -6.548 kJmol −1 while for 2 M HCl it was found to be -5.290 kJmol −1 , respectively.…”
Section: Adsorption Isothermmentioning
confidence: 99%