Volume 3: Combustion, Fire and Reacting Flow; Heat Transfer in Multiphase Systems; Heat Transfer in Transport Phenomena in Manu 2009
DOI: 10.1115/ht2009-88520 View full text |Buy / Rent full text
|
|

Abstract: A series of fire tests was conducted involving a 2.44-m-(8-ft)-diameter, 4.57-m-(15-ft)-long, 2.54-cm-(1-inch)-wall thickness pipe calorimeter suspended 1-m above a 7.93-m-diameter pool that contained 7.57 m3 (2000 gallons) of jet fuel. The wind conditions, calorimeter temperature, participating media temperature and speed, and radiant heat flux, were measured at several locations as functions of time in three fire tests. The first two had relatively light winds and lasted roughly 40 minutes, while the third h… Show more

Help me understand this report

Search citation statements

Order By: Relevance
Select...
2
1
0
3
0

Year Published

2010
2010
2011
2011

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

0
3
0
Order By: Relevance
“…Large-scale outdoor fire tests have been performed to acquire data to benchmark CAFE for large-scale outdoor fires [19,20]. In these experiments, large pipe calorimeters were suspended over JP8 jet fuel fires.…”
Section: Container Analysis Fire Environment Simulationsmentioning
See 1 more Smart Citation
Create an account to read the remaining citation statements from this report. You will also get access to:
  • Search over 1b+ citation statments to see what is being said about any topic in the research literature
  • Advanced Search to find publications that support or contrast your research
  • Citation reports and visualizations to easily see what publications are saying about each other
  • Browser extension to see Smart Citations wherever you read research
  • Dashboards to evaluate and keep track of groups of publications
  • Alerts to stay on top of citations as they happen
  • Automated reference checks to make sure you are citing reliable research in your manuscripts
  • 14 day free preview of our premium features.

Trusted by researchers and organizations around the world

Over 100,000 students researchers, and industry experts at use scite

See what students are saying

rupbmjkragerfmgwileyiopcupepmcmbcthiemesagefrontiersapsiucrarxivemeralduhksmucshluniversity-of-gavle
“…Large-scale outdoor fire tests have been performed to acquire data to benchmark CAFE for large-scale outdoor fires [19,20]. In these experiments, large pipe calorimeters were suspended over JP8 jet fuel fires.…”
Section: Container Analysis Fire Environment Simulationsmentioning
“…The values of these parameters must be determined based on comparison of CAFE simulation results with measured data acquired in large fire experiments [17,18]. Large-scale outdoor fire tests have been performed to acquire data to benchmark CAFE for large-scale outdoor fires [19,20]. In these experiments, large pipe calorimeters were suspended over JP8 jet fuel fires.…”
Section: Container Analysis Fire Environment Simulationsmentioning
“…Large-scale outdoor fire tests have been performed to acquire data to benchmark CAFE [8,9]. In these experiments, truck-and rail-package-sized pipe calorimeters were suspended over JP8 jet fuel fires.…”
Section: Introductionmentioning