2011
DOI: 10.1063/1.3596450
|View full text |Cite
|
Sign up to set email alerts
|

Thermal emittance measurements of a cesium potassium antimonide photocathode

Abstract: Thermal emittance measurements of a CsK 2 Sb photocathode at several laser wavelengths are presented. The emittance is obtained with a solenoid scan technique using a high voltage dc photoemission gun. The thermal emittance is 0.56 ± 0.03 mm mrad/mm(rms) at 532 nm wavelength. The results are compared with a simple photoemission model and found to be in a good agreement.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
65
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 72 publications
(71 citation statements)
references
References 5 publications
(3 reference statements)
4
65
1
Order By: Relevance
“…A cathode intrinsic emittance of 0.5-0.6 μm per mm rms was measured in the gun over several cathodes at 532 nm. This measurement agrees well with the previous intrinsic emittance measurements of K-Cs-Sb cathodes in dc guns [14]. No evidence of QE depletion in the cathode central area due to ion back-bombardment or heating or sputtering induced by the laser used for inducing photoemission from the cathode was found.…”
Section: B Photocathode Performancesupporting
confidence: 81%
“…A cathode intrinsic emittance of 0.5-0.6 μm per mm rms was measured in the gun over several cathodes at 532 nm. This measurement agrees well with the previous intrinsic emittance measurements of K-Cs-Sb cathodes in dc guns [14]. No evidence of QE depletion in the cathode central area due to ion back-bombardment or heating or sputtering induced by the laser used for inducing photoemission from the cathode was found.…”
Section: B Photocathode Performancesupporting
confidence: 81%
“…[14]. Other groups report higher QE at 532 nm, of the order of 8% [2,3], suggesting our growth procedure is not optimized.…”
Section: Experiments a Photocathode Preparationmentioning
confidence: 98%
“…15(b), was found to be 0:73 AE 0:06 mm mrad=mmðrmsÞ at 532 nm. We did not intend to perform a rigorous thermal emittance measurement; however our normalized rms emittance per laser size values is reasonable considering previously reported thermal emittance values [2]. Emittance measurements are summarized in Table II.…”
Section: F Emittance Measurementsmentioning
confidence: 99%
See 2 more Smart Citations