2009
DOI: 10.1248/bpb.32.1354
|View full text |Cite
|
Sign up to set email alerts
|

The Protective Effect of Daming Capsule on Heart Function in Streptozocin-Induced Diabetic Rats with Hyperlipidemia

Abstract: Impaired heart function is the main reason for increased mortality of diabetes mellitus. Development of drugs with cardioprotective effects against diabetic myocardiopathy would benefit patients with diabetes. In this study, we tested the cardioprotective effects of Daming capsule (DMC), a traditional Chinese formula, on heart function in streptozocin (STZ)-induced diabetic rats with high fat-diet (HFD). DMC 100 mg/kg/d markedly decreased fasting blood glucose (FBG) and total cholesterol (TC), but did not affe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
25
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
10

Relationship

5
5

Authors

Journals

citations
Cited by 22 publications
(26 citation statements)
references
References 30 publications
1
25
0
Order By: Relevance
“…Heart functions of all rats were measured according to our previous study [21]. Systolic blood pressure (SBP) and heart rate (HR) were monitored by a catheter that was inserted through the right common carotid artery and into the left ventricle.…”
Section: Methodsmentioning
confidence: 99%
“…Heart functions of all rats were measured according to our previous study [21]. Systolic blood pressure (SBP) and heart rate (HR) were monitored by a catheter that was inserted through the right common carotid artery and into the left ventricle.…”
Section: Methodsmentioning
confidence: 99%
“…injection. According to previous study [23], cardiac function of all rats was studied. Briefly, arterial blood pressure (ABP) and heart rate (HR) were recorded by inserting the catheter into the left ventricle through the right common carotid artery.…”
Section: Evaluation Of Body Weight Food and Drink Consumption And Bimentioning
confidence: 99%
“…Cardiac function was calculated as previously described [16] ; briefly, the catheter was inserted into the left ventricle via the right common carotid artery to record cardiac electrophysiologic parameters. Arterial blood pressure (ABP), heart rate (HR), left ventricular systolic pressure (LVSP), left ventricular diastolic pressure (LVEDP) and the maximum rate of change in left ventricular pressure in the isovolumic contraction or relaxation period (±dp/dt max ) were measured using a BL-420 Data Acquisition & Analysis System (Chengdu Tme Technology Co, Ltd, China).…”
Section: Biochemical Indexes Of Bloodmentioning
confidence: 99%