2018
DOI: 10.1016/j.meatsci.2018.03.006
|View full text |Cite
|
Sign up to set email alerts
|

The impact of frozen storage duration on physical, chemical and microbiological properties of pork

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

10
27
1
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 66 publications
(46 citation statements)
references
References 45 publications
10
27
1
2
Order By: Relevance
“…A significant increase in TBA contents was observed in treated meat samples. Similar results were reported by Medić et al (2018) in pork meat. These increases are due to production of free radicals, which attach the unsaturated fatty acids leading to formation of peroxides and hydroperoxides; its breakdown resulted in unacceptable odors and flavors (Raeisi et al, 2018).…”
Section: Chemical Evaluationsupporting
confidence: 91%
“…A significant increase in TBA contents was observed in treated meat samples. Similar results were reported by Medić et al (2018) in pork meat. These increases are due to production of free radicals, which attach the unsaturated fatty acids leading to formation of peroxides and hydroperoxides; its breakdown resulted in unacceptable odors and flavors (Raeisi et al, 2018).…”
Section: Chemical Evaluationsupporting
confidence: 91%
“…Test samples were prepared according to the method described by Helga et al [20] The determination of microbiological counts was performed according to Zhang et al [21] Meat samples (25 g) were homogenized 5 min using a homogenizer (Ultra-turax T25 basic, IKA-WERKE, Germany) and then diluted completely with 250 ml sterile saline solution (0.85% NaCl). One milliliter of each sample solution was spread on the surface of different selective agars.…”
Section: Microbial Analysismentioning
confidence: 99%
“…The results of the present study are in agreement acid methyl esters (FAMEs) for gas chromatography (GC) analysis according to ISO 12966-2:2011. The procedure of preparing the samples for GC analysis and determination of fatty acid composition is described in detail by Medić et al (2018). The determination of fatty acid composition was performed using GC/MS 5975C device (Agilent Technologies, Palo Alto, CA, USA) equipped with flame ionization detector and split/splitless injector.…”
Section: Fatty Acid Composition Of Baranjski Kulen From Two Diverse Pmentioning
confidence: 99%