2019
DOI: 10.1016/j.jvs.2018.11.015
|View full text |Cite
|
Sign up to set email alerts
|

The GORE TAG conformable thoracic stent graft with the new ACTIVE CONTROL deployment system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 13 publications
1
7
0
Order By: Relevance
“…Finally, retrograde dissection is a devastating complication of TEVAR and the incidence is low overall, but more common as total TEVAR numbers increase. Like Mariani et al, we observed no retrograde dissection [24]. In comparison, other TEVAR studies have reported incidences of 1-2.3% [7,20,22].…”
Section: Plos Onesupporting
confidence: 77%
See 1 more Smart Citation
“…Finally, retrograde dissection is a devastating complication of TEVAR and the incidence is low overall, but more common as total TEVAR numbers increase. Like Mariani et al, we observed no retrograde dissection [24]. In comparison, other TEVAR studies have reported incidences of 1-2.3% [7,20,22].…”
Section: Plos Onesupporting
confidence: 77%
“…TEVAR outcomes are determined in part by stent-graft deployment accuracy and apposition. As experience with TEVAR grows, so too does the sophistication with which we measure outcomes as well sensitivity to variability in pathology, anatomy and use; the Gore cTAG with an active control deployment system demonstrated 100% accuracy in 20 patients with landing zone �3 and aortic arch types I (n = 1), II (n = 10), and III (n = 9) [24]. The previous generation RelayPlus NBS demonstrated accurate deployment in the aortic arch in 78 patients with a wide variety of thoracic pathologies involving arch zones 2 (44%) and 3 (54%): aortic arch type…”
Section: Discussionmentioning
confidence: 99%
“…Accordingly, no bird-beak configuration was observed in the current cohort, and the rate of type Ia endoleak was low even though half of the endografts were implanted in zones 0 to 2. Mariani et al 12 reported the early results of the CTAG in 30 patients; they achieved a 100% technical success rate without type Ia endoleak, bird-beak configuration, or retrograde aortic arch dissection. The Conformable GORE TAG Endoprosthesis European Registry for thoracic arch pathologies found a comparable technical success of 92% and a low (4%) endoleak rate.…”
Section: Discussionmentioning
confidence: 99%
“…26,27 This has been reported to reduce rates of EL-Ia, at least in “suitable” TAA with sufficient PLZ. 28,29 On the other hand, justified doubt remains regarding the durability of oIFU–LZ as FU is usually limited, especially in real-world studies.…”
Section: Discussionmentioning
confidence: 99%