2009
DOI: 10.1080/14767050902822229
|View full text |Cite
|
Sign up to set email alerts
|

The effects of transient systemic hypotension on renal oxidative status, morphology and plasma nitric oxide levels in pregnant rats

Abstract: The findings of this study show that transient hypotension induces a kidney injury in pregnant rats. MDA and GSH in kidneys seem to play a role in the pathophysiology of this injury. However, the roles of antioxidant enzymes and NO and the other underlying mechanisms deserve and necessitate further investigation regarding the long-term health of the mother and fetus.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 45 publications
0
4
0
Order By: Relevance
“…Oxytocin infusions were used prophylactically at obstetric request in 45 women (75%), at a standardised dose of 10 IU in 125 mL every hour for the first 4 h. Urine output during the first 6 h and at 12 and 18 h, according to body weight, are shown in Table 1, for the whole group and according to whether oxytocin infusion was used. Median (95% CI) 24-h intravenous fluid input were 2.8 (1.8-4.3) L. Median (IQR [range]) times to first oral fluids and cessation of intravenous fluid were 3 (2-4 [2][3][4][5][6][7][8][9][10][11]) h and 6 (5-7 [2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21]) h. Mean (±SD) haemoglobin concentrations on the day of surgery and the following day were 11.9 (±1.2) and 10.5 (±1.0) g/dL, respectively. The mean (±SD) drop in haemoglobin concentration with or without oxytocin infusion was 1.4 (±0.9) and 1.4 (±0.4) mg/dL respectively; no patient received blood products.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Oxytocin infusions were used prophylactically at obstetric request in 45 women (75%), at a standardised dose of 10 IU in 125 mL every hour for the first 4 h. Urine output during the first 6 h and at 12 and 18 h, according to body weight, are shown in Table 1, for the whole group and according to whether oxytocin infusion was used. Median (95% CI) 24-h intravenous fluid input were 2.8 (1.8-4.3) L. Median (IQR [range]) times to first oral fluids and cessation of intravenous fluid were 3 (2-4 [2][3][4][5][6][7][8][9][10][11]) h and 6 (5-7 [2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21]) h. Mean (±SD) haemoglobin concentrations on the day of surgery and the following day were 11.9 (±1.2) and 10.5 (±1.0) g/dL, respectively. The mean (±SD) drop in haemoglobin concentration with or without oxytocin infusion was 1.4 (±0.9) and 1.4 (±0.4) mg/dL respectively; no patient received blood products.…”
Section: Resultsmentioning
confidence: 99%
“…6 Conditions such as preeclampsia may involve renal impairment, and various potential influences on renal function such as neuraxial anaesthesia, blood loss, and drugs such as non-steroidal anti-inflammatory drugs and oxytocin during or after labour and delivery may be significant. [7][8][9] Without accurate information on normal urine output, it is hard to set goals for women who may be at risk of renal dysfunction. The aim of this observational study was to establish a normal range for urine output after elective caesarean section under neuraxial anaesthesia in healthy women.…”
Section: Introductionmentioning
confidence: 99%
“…The catheterised femoral artery was joined to a pressure transducer (BIOPAC SS13L, BIOPAC Systems Inc., California, USA), which was connected to a data acquisition/analysis system (BIOPAC MP30, BIOPAC Systems Inc., California, USA) to monitor blood pressure. After a 30-minute stabilisation period following catheterisation, systemic hypotension was induced by blood withdrawal (approximately 1 mL per 100 g body weight) within 5 minutes in hypotension groups, as described previously (10,11). As clamping of the uterine vasculature for 30 minutes was previously reported to be sufficient to cause damage in the foetal brain (12), mean arterial blood pressure (MABP) was maintained at 50 mmHg for a period of 30 minutes.…”
Section: Experimental Protocolmentioning
confidence: 99%
“…The body temperature was monitored and maintained at 37 °C during anesthesia. The hypotension procedure was performed on day 15 of gestation as described previously (22). Briefly, the right femoral artery was cannulated and attached to a pressure transducer (BIOPAC SS13L, BIOPAC Systems Inc., CA, USA).…”
Section: Animals and Experimental Protocolmentioning
confidence: 99%