2014
DOI: 10.1016/j.ultras.2014.04.010
|View full text |Cite
|
Sign up to set email alerts
|

The development of a shock-tube based characterization technique for air-coupled ultrasonic probes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…Compared with micro‐sinusoidal pressure standard [2], sinusoidal pressure standard [2, 3], and quick‐opening valve dynamic pressure standard [2], shock tube‐based dynamic pressure standard [4, 5] was chosen because its range of step pressure covered most of the dynamic pressure transducers' measuring range in CARDC. The performance index of shock tube‐based dynamic pressure standard [6]: the range of the step pressure should be 15 kPa–1 MPa; the rise time of the step pressure should be <1 μs; the duration of the step pressure plateau should be >4 ms; the fluctuation of the step pressure plateau should be within ± 2%; the second ‐ order expand uncertainty of the step pressure should be <4%.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with micro‐sinusoidal pressure standard [2], sinusoidal pressure standard [2, 3], and quick‐opening valve dynamic pressure standard [2], shock tube‐based dynamic pressure standard [4, 5] was chosen because its range of step pressure covered most of the dynamic pressure transducers' measuring range in CARDC. The performance index of shock tube‐based dynamic pressure standard [6]: the range of the step pressure should be 15 kPa–1 MPa; the rise time of the step pressure should be <1 μs; the duration of the step pressure plateau should be >4 ms; the fluctuation of the step pressure plateau should be within ± 2%; the second ‐ order expand uncertainty of the step pressure should be <4%.…”
Section: Introductionmentioning
confidence: 99%
“…Shock tube was used for the calibration of dynamic pressure transducers because it was an ideal generator of step pressure [3][4][5][6]. According to the 'Verification Regulation of Dynamic Pressure standards' [7], the shock tube based dynamic pressure standard should meet all demand of performance index showed in table 1. order expand uncertainty of the step pressure generated by the calibration installation was specially studied.…”
Section: Introductionmentioning
confidence: 99%
“…Pressure sensors have been widely used to measure dynamic pressure signals in intelligent control, wind tunnel test, flight test, and so on [ 1 ]. The dynamic performance parameters of a pressure sensor are the important indicators of its dynamic measurement capability and are also the main basis to judge whether the needs of a dynamic pressure measurement are met [ 1 , 2 ].…”
Section: Introductionmentioning
confidence: 99%
“…Since the shock tube was created in 20th century, it has been widely used in a variety of dynamic experiments. A shock tube can produce a high-speed shock wave and a subsequent step pressure, making it ideal dynamic equipment for calibrating pressure sensors [ 1 ]. In 2002, the Instrument Society of America published an important work titled “A Guide for the Dynamic Calibration of Pressure Transducers”, which considered shock tube calibration as the most important calibration methods [ 2 ].…”
Section: Introductionmentioning
confidence: 99%