2009
DOI: 10.1016/j.ultrasmedbio.2009.03.015
|View full text |Cite
|
Sign up to set email alerts
|

The Automated Assessment of Ultrasound Scanner Lateral and Slice Thickness Resolution: Use of the Step Response

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 9 publications
0
12
0
Order By: Relevance
“…Thus far, we have only evaluated US QC tests required by our accrediting organization (American College of Radiology). Recently, several new and novel methods of objective assessment of ultrasound equipment performance have been proposed (e.g., Kofler et al 2001;Satrapa et al 2006;Dolezal et al 2007;Rowland et al 2009;MacGillivray et al 2010). For pre-purchase testing purposes, we have employed a test to assess spherical target detectability, similar to work reported by Kofler et al 2001.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus far, we have only evaluated US QC tests required by our accrediting organization (American College of Radiology). Recently, several new and novel methods of objective assessment of ultrasound equipment performance have been proposed (e.g., Kofler et al 2001;Satrapa et al 2006;Dolezal et al 2007;Rowland et al 2009;MacGillivray et al 2010). For pre-purchase testing purposes, we have employed a test to assess spherical target detectability, similar to work reported by Kofler et al 2001.…”
Section: Discussionmentioning
confidence: 99%
“…Recommended ultrasound performance tests and measurement approaches based on subjective and manual methods, as well as objective computer-based analysis of phantom images have been described in the literature (Goldstein et al 1989;Goodsitt et al 1998;Gibson et al 2001;Kofler et al 2001;Satrapa et al 2006;Dolezal et al 2007;Thijssen et al 2007;Rowland et al 2009;MacGillivray et al 2010). Dedicated commercial tools for testing US transducers have also been reported (Moore et al 2005).…”
Section: Introductionmentioning
confidence: 99%
“…Due to the subjective nature of visual inspection, computerized automated evaluation of parameters of US images has been considered [10,11,21-24]. A relatively high subjectivity of visual inspection has been reported [25].…”
Section: Discussionmentioning
confidence: 99%
“…Thijssen et al reported and implemented a test protocol including a series of quantitative measurements of overall dynamic range, sensitivity, contrast resolution, and spatial resolution 3. Other methods for quantitatively assessing metrics such as resolution integral, depth of penetration (DOP), entropy, correlation, clutter, and spherical target detection have also been proposed 4, 5, 6, 7, 8, 9…”
Section: Introductionmentioning
confidence: 99%