2015
DOI: 10.1134/s10704272150120150
|View full text |Cite
|
Sign up to set email alerts
|

Substantiation of the operating life of gas piezosensors in detection of vapors of organic compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
7
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 10 publications
2
7
0
1
Order By: Relevance
“…Films of 18C6, Tween were chosen for the detection of carboxylic and hydroxy acids [ 47 , 48 ], and MCNT, BCB, MR for ammonia and amines [ 49 , 50 , 51 ]. PEGSb was selected for detection of acids, alcohols, ketones [ 52 , 53 ], and TX-100 for nitrogen- and sulfur-containing compounds [ 54 , 55 ]. Moreover, the selected films are stable for at least a year when analyzing small amounts of volatile substances [ 53 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Films of 18C6, Tween were chosen for the detection of carboxylic and hydroxy acids [ 47 , 48 ], and MCNT, BCB, MR for ammonia and amines [ 49 , 50 , 51 ]. PEGSb was selected for detection of acids, alcohols, ketones [ 52 , 53 ], and TX-100 for nitrogen- and sulfur-containing compounds [ 54 , 55 ]. Moreover, the selected films are stable for at least a year when analyzing small amounts of volatile substances [ 53 ].…”
Section: Methodsmentioning
confidence: 99%
“…PEGSb was selected for detection of acids, alcohols, ketones [ 52 , 53 ], and TX-100 for nitrogen- and sulfur-containing compounds [ 54 , 55 ]. Moreover, the selected films are stable for at least a year when analyzing small amounts of volatile substances [ 53 ]. Therefore, the resulting array should be effective for solving the problem.…”
Section: Methodsmentioning
confidence: 99%
“…The instrument software recorded the integral responses of sensors (∆ F i , Hz) versus time in the form of chronofrequency patterns and their analytical signals (∆ F max, i ) as maximum changes in the sensor responses during the measurement, which were automatically determined in the software based on the chronofrequency patterns [ 22 ]. The sensors were fabricated in accordance with previously described procedures [ 23 ].…”
Section: Methodsmentioning
confidence: 99%
“…The sensors were chosen to make an array based on their high sensitivity to various classes of volatile substances, including the biomarkers of diseases in urine [ 7 12 ]: DCH18C6 and Tween-40 films were chosen for the detection of carboxylic and hydroxy acids [ 24 , 25 ]; MWCNTs, BCB, and MR were used for ammonia and structurally different amines [ 26 28 ]; PEGSb was used for ketones and organic acids [ 24 , 29 , 30 ]; and TX-100 was used for nitrogen- and sulfur-containing compounds [ 30 , 31 ]. Moreover, the selected films were stable for at least a year in the analysis of small amounts of volatile substances [ 22 ] contained in biosamples. Therefore, the resulting array should be effective for solving the problem.…”
Section: Methodsmentioning
confidence: 99%
“…К многомерным аналитическим сигналам относятся отклики мультисенсорных систем типа искусственных "носа, глаза, языка". Для таких систем не характерны, но возможны традиционные качественный (идентификация отдельных компонентов сложных смесей) и количественный (определение содержания каждого компонента) анализ [1][2][3][4][5]. Для сравнения двух и более проб, для установления причин возможных различий их состояния применяют метод хемометрикиметод обработки сразу всех матриц выходных данных.…”
Section: Introductionunclassified