2014
DOI: 10.1590/s1516-14392014005000042
|View full text |Cite
|
Sign up to set email alerts
|

Study of the influence of acid etching treatments on the superficial characteristics of Ti

Abstract: Modifications in texture and surface chemistry are commonly used to increase the biologic response to implants. We evaluated the influence of five different acid etching treatments on the chemical and topographical superficial characteristics of cpTi grade IV discs (test groups). One group of samples were only polished (control group). The samples were analyzed by electron microscopy (SEM, EDS), atomic force microscopy, and grazing incidence XRD. The acid etching treatments which produced higher values for the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
9
1

Relationship

5
5

Authors

Journals

citations
Cited by 43 publications
(27 citation statements)
references
References 25 publications
0
26
0
Order By: Relevance
“…It is known that the surface properties of dental implants such as topography and chemistry are relevant for the osseointegration process influencing ionic interaction, protein adsorption and cellular activity at the surface. 101 Titanium with different surface modifications shows a wide range of chemical, physical properties, and surface topographies or morphologies, depending on how they are prepared and handled, [102][103][104] and it is not clear whether, in general, one surface modification is better than another. 101 It is important to stress that some publications on postextraction implants have a short-term follow-up period, of up to 1 year.…”
Section: Discussionmentioning
confidence: 99%
“…It is known that the surface properties of dental implants such as topography and chemistry are relevant for the osseointegration process influencing ionic interaction, protein adsorption and cellular activity at the surface. 101 Titanium with different surface modifications shows a wide range of chemical, physical properties, and surface topographies or morphologies, depending on how they are prepared and handled, [102][103][104] and it is not clear whether, in general, one surface modification is better than another. 101 It is important to stress that some publications on postextraction implants have a short-term follow-up period, of up to 1 year.…”
Section: Discussionmentioning
confidence: 99%
“…65 The studies here included implants of different brands and surface treatments. Titanium with different surface modifications shows a wide range of chemical, physical properties, and surface topographies or morphologies, depending on how they are prepared and handled, [66][67][68] and it is not clear whether, in general, one surface modification is better than another. 65 Concerning the angulation of the implants, one should recall that in the interpretation of the results, the classification of tilted and axially placed implants was based on the assessment of the inclination in only the mesial-distal direction.…”
Section: Discussionmentioning
confidence: 99%
“…The moderate micro-roughness of most modern implants did not seem coupled to more than 1-2% of periimplantitis when followed up for 10 years or more as indicated in a recent review of ten different long term clinical reports of Tioblast, SLA and TiUnite implants. 38 Titanium with different surface modifications shows a wide range of chemical, physical properties, and surface topographies or morphologies, depending on how they are prepared and handled, [39][40][41] and it is not clear whether, in general, one surface modification is better than another. 42 Another possible limitation of some studies is that implants were not tested for stability during some of the late follow-up visits since many of the prostheses could not be removed because they were permanently cemented.…”
Section: Discussionmentioning
confidence: 99%