2018
DOI: 10.1007/s00339-018-2195-z
|View full text |Cite
|
Sign up to set email alerts
|

Strong third-order optical nonlinearities of Ag nanoparticles synthesized by laser ablation of bulk silver in water and air

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 24 publications
(13 citation statements)
references
References 43 publications
0
12
1
Order By: Relevance
“…Notice that in our case, we present the nonlinear absorption coefficient of the suspension (not a single NP), which was just two orders of magnitude smaller (3 × 10 −7 cm W −1 ) than the one of Ag NPs reported in Ref. [38]. It means that once we assume the similar volume part of chemically prepared NPs in our suspension (10 -3 ), the NP nonlinear absorption coefficient will surpass the one in the case of ablation-produced silver nanoparticles.…”
Section: Discussioncontrasting
confidence: 61%
See 1 more Smart Citation
“…Notice that in our case, we present the nonlinear absorption coefficient of the suspension (not a single NP), which was just two orders of magnitude smaller (3 × 10 −7 cm W −1 ) than the one of Ag NPs reported in Ref. [38]. It means that once we assume the similar volume part of chemically prepared NPs in our suspension (10 -3 ), the NP nonlinear absorption coefficient will surpass the one in the case of ablation-produced silver nanoparticles.…”
Section: Discussioncontrasting
confidence: 61%
“…Recently, the nonlinear optical studies of the Ag NPs prepared by another method, i.e., during ablation of bulk silver in water using different wavelengths and durations of heating pulses, were reported [38]. The joint appearance of nonlinear optical refraction and absorption was analyzed using the 1064 nm, 5 ns and 800 nm, 60 fs probe pulses.…”
Section: Discussionmentioning
confidence: 99%
“…This results in the decrease in the transmittance as the sample further moves toward the focus indicating the combined ramification of SA and TPA processes. Recently, several groups have measured the NLO properties of the Ag NPs with various laser pulse widths [26,48,49]. Particularly, the comparison of the application of 200 ps and 60 fs pulses, which clearly depict the effect of long pulses on the NLO properties of NPs, has been reported in [48].…”
Section: Resultsmentioning
confidence: 99%
“…These processes depend not only on the intensity of the incident photon but also on the frequency of the incident photon which plays an important role in their NLO properties depending on the resonant or nonresonant transitions. There are few reports on the competitive behavior of SA and RSA together due to the associated energy level of metal NPs, which provide the possibility to be investigated with the variation of the size of NPs [8,26].…”
Section: Introductionmentioning
confidence: 99%
“…The beam diameter on the ablating surface was 0.3 mm. Details of the experimental setup are given elsewhere [53,54,55].…”
Section: Methodsmentioning
confidence: 99%