2010
DOI: 10.1007/s00604-010-0329-x
|View full text |Cite
|
Sign up to set email alerts
|

Stripping voltammetric determination of mercury(II) and lead(II) using screen-printed electrodes modified with gold films, and metal ion preconcentration with thiol-modified magnetic particles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
48
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 108 publications
(51 citation statements)
references
References 35 publications
1
48
0
Order By: Relevance
“…In Table 1 the detection limit of the determination of mercury obtained from a related technique using stripping voltammetry is shown. [19][20][21][22][23] The detection limit of the present method is observed to be better or comparable with the literature reports in similar fields. Additionally, the present method is devoted more to the determination of mercury in the presence of high concentrations of Co 2+ .…”
Section: Resultssupporting
confidence: 84%
“…In Table 1 the detection limit of the determination of mercury obtained from a related technique using stripping voltammetry is shown. [19][20][21][22][23] The detection limit of the present method is observed to be better or comparable with the literature reports in similar fields. Additionally, the present method is devoted more to the determination of mercury in the presence of high concentrations of Co 2+ .…”
Section: Resultssupporting
confidence: 84%
“…Ultrasounds frequency (KHz) 37 80 Tap water 106 (11) 108 (7) Bottled water 98 (11) 103 (15) River water 97 (10) 98 (9) Wastewater 97 (12) 95 (9) …”
Section: Discussionmentioning
confidence: 99%
“…It is important to point out that the sensitivity and LOD of the proposed method are significantly better than those obtained in a previous work [14] (i.e., 0.120 µA µg -1 L and 3.3 µg L -1 , respectively) using the same kind of SPCnAuEs under equal conditions but without sample preparation. In addition, just a few of the reported works using SPEs have shown equal or lower LOD than 0.2 µg L -1 [10,12,14], however, standard…”
Section: Analytical Figures Of Meritmentioning
confidence: 98%
See 1 more Smart Citation
“…SPE enables detection method incorporated in portable systems, an important requirement for real-time, non-invasive analysis of a sample, without alteration of the "natural environmental conditions". The recent possibility of designing and fabricating SPE, including microelectrodes and chemically modified electrodes and incorporating these in a variety of highly sensitive biosensors, has increased industrial, clinical, and environmental interest [15,18]. SPEs are more versatile in practical preparation machine-controlled manufacturing thus enabling possible mass production at low costs, small dimensions, and planar configuration [15].…”
Section: Micro-engineering and Micro-fabrication Technologymentioning
confidence: 99%