1989
DOI: 10.1288/00005537-198902000-00012
|View full text |Cite
|
Sign up to set email alerts
|

Stomal complications and airflow line problems of the communi‐trach I® cuffed talking tracheotomy tube

Abstract: There have been no reports of stomal complications and airflow line problems associated with a cuffed talking tracheotomy tube. However, the results of this study showed that stomal complications, in the form of pressure necrosis and wound extension, and problems with airflow line kinking occurred with a 40% and 80% frequency, respectively. Solutions to both difficulties are discussed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

1991
1991
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 5 publications
0
13
0
Order By: Relevance
“…Currently there are six types of specialized talking tracheostomy tubes available to allow communication with an inflated cuff [ 49 ]. The Portex Trach-Talk [ 36 , 39 , 42 ] and Communi-Trach I [ 42 , 56 ] were used with four case series. The Portex BLUSA Tracheostomy Tube was reported in one article with four case reports [ 49 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Currently there are six types of specialized talking tracheostomy tubes available to allow communication with an inflated cuff [ 49 ]. The Portex Trach-Talk [ 36 , 39 , 42 ] and Communi-Trach I [ 42 , 56 ] were used with four case series. The Portex BLUSA Tracheostomy Tube was reported in one article with four case reports [ 49 ].…”
Section: Resultsmentioning
confidence: 99%
“…These tracheostomy tubes have an additional lumen above the cuff through which air can flow into the larynx to facilitate verbal communication. Intelligible speech, measured by a subjective assessment of improvement of speech, was created in 100 % ( n = 20) [ 39 ] and 74 % ( n = 14) [ 36 ] using the Portex Trach Talk, in 90 % ( n = 18) with the Communi-Trach I [ 56 ], and in 79 % ( n = 15) using the Portex Trach-Talk and the Communi-Trach I (both or one of them were used) [ 42 ]. With the BLUSA tube, all patients ( n = 4) achieved adequate phonation [ 49 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, these tubes rely on use of the patient's own oral-pharyngeal mechanism [ 10]; allow speech throughout the whole of the respiratory cycle [1,11]; and permit maintenance of pre-set ventilator volumes and accurate monitoring of tidal volumes [ l ]. However, the disadvantages of "speaking tracheostomy tubes" are numerous: interference by secretions, difficulty in positioning the tube, problematic design of the tube, and altered voice quality [10, [12][13][14].…”
Section: Patientmentioning
confidence: 99%
“…The drying effect, including the potential for laryngeal injury of continuous nonhumidified air running through the glottis, is also a potential problem area with above cuff vocalisation [83].…”
Section: Verbal Communication Options Suitable For Non-ventilated Andmentioning
confidence: 99%