Medical Imaging 2013: Physics of Medical Imaging 2013
DOI: 10.1117/12.2007993
|View full text |Cite
|
Sign up to set email alerts
|

Stationary chest tomosynthesis using a CNT x-ray source array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 16 publications
(19 citation statements)
references
References 12 publications
0
19
0
Order By: Relevance
“…A simple linear multiple source using an array of 31 CNT FE cathodes has also been constructed, for the purposes to digital breast tomosynthesis, which was shown to be capable of a total scan angle of 30° [171]. In a further extension, a digital chest tomosynthesis scanner was demonstrated [238]. This system used 75 CNT FE sources, operating at up to 80 kV with a 20°beam angle.…”
Section: Static Tomography and Tomosynthesismentioning
confidence: 98%
“…A simple linear multiple source using an array of 31 CNT FE cathodes has also been constructed, for the purposes to digital breast tomosynthesis, which was shown to be capable of a total scan angle of 30° [171]. In a further extension, a digital chest tomosynthesis scanner was demonstrated [238]. This system used 75 CNT FE sources, operating at up to 80 kV with a 20°beam angle.…”
Section: Static Tomography and Tomosynthesismentioning
confidence: 98%
“…19,22 The modulation transfer function (MTF) is 1.7cycles/min in the scanning direction and 3.4 cycles/min in the perpendicular direction. 19 The anode is made of tungsten and there is 2.8mm of aluminum for filtration. The anode voltage is set by using a Spellman High Voltage Power Supply (model XRV160P1800).…”
Section: S-dct Systemmentioning
confidence: 99%
“…[15][16][17] Using the x-ray source array, the stationary digital chest tomosynthesis (s-DCT) system can achieve full angular coverage in tomosynthesis imaging with no moving parts. 14,[18][19][20] Previous studies on the stability and geometry of the s-DCT system have been published. 21,19,22,23 The purpose of this study was to evaluate the feasibility of using the prototype s-DCT device for patient imaging.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Multiple individually controllable X-ray sources are spatially distributed in a single X-ray tube to eliminate the need to position the X-ray source at different locations during image acquisition. This technology enables stationary tomography, which has been demonstrated in digital breast tomosynthesis, 32-34 digital chest tomosynthesis, 35,36 tomosynthesis-guided radiation therapy 37 and stationary CT for homeland security. 38 The purpose of this study was to investigate the feasibility of using a CNT X-ray source array for stationary intraoral tomosynthesis (s-IOT).…”
Section: Introductionmentioning
confidence: 99%