2015
Stability-indicating HPLC and PLS chemometric methods for the determination of acemetacin in presence of its degradation products and impurities
Abstract: Two stability-indicating methods were developed and validated for the quantitative determination of acemetacin (ACM) in presence of its degradation products and impurities. The first method was based on separation of ACM from its degradation products and impurities by RP-HPLC on Inertsil C8 column (150 × 4.6 mm i.d) using a mobile phase composed of 0.02 M phosphate buffer: methanol (35:65, v:v, pH = 6.5). The flow rate was adjusted at 1 mL/min and quantification was achieved with UV detection at 245 nm using m…
Search citation statements
Paper Sections
Select...
3
2
0
0
Citation Types
0
8
0
0
Year Published
2016
2021
Publication Types
Select...
4
Relationship
0
4
Authors
Journals
Cited by 4 publications
(8 citation statements)
References 29 publications
0
8
0
0
“…The British Pharmacopoeia [9] described indomethacin and p-chlorobenzoic acid (PCBA) as impurities for ACM. p-Chlorobenzoic acid and 5-methoxy-2-methyl-3-indole acetic acid are reported as the degradation products under specific alkaline and acidic stress conditions [5]. These degradation products obtained were confirmed by their m/z using UPLC-MS/MS.…”
Section: Introductionmentioning
confidence: 70%
“…The British Pharmacopoeia [9] described indomethacin and p-chlorobenzoic acid (PCBA) as impurities for ACM. p-Chlorobenzoic acid and 5-methoxy-2-methyl-3-indole acetic acid are reported as the degradation products under specific alkaline and acidic stress conditions [5]. These degradation products obtained were confirmed by their m/z using UPLC-MS/MS.…”
Section: Introductionmentioning
confidence: 70%
“…ACM under different stressed acidic (reflux with 0.1 N HCl for 3 hrs in boiling water bath) and basic (0.1 N NaOH for 30 min at room temperature) conditions undergo complete degradation, where it is stable under oxidative and thermal stress conditions as reported [5]. ACM was degradated into PCBA and 5-methoxy-2-methyl-3-indole acetic acid as reported [5], which confirmed by their molecular weights m/z 156.32, 220.30 using the proposed method (Full scan). So, by applying the proposed UPLC-MS/MS technique, it was probable to detect ACM in the presence of its metabolite and/or degradation products in short time (˂ 1 min) as shown in Figure 2.…”
Section: Degradationmentioning
confidence: 84%
“…2021 -European Journal of Chemistry -CC BY NC -DOI: 10.5155/eurjchem.12.4.368-376.2144 For both PLS-2 and PCR, the concentration residuals were plotted against the actual concentrations of the prepared mixtures (Figures 7 and 8), and the residuals for all samples were found to be randomly distributed around zero [25][26][27][28][29][30][31][32][33]. The average recoveries of each drug using PLS-2 and PCR methods are summarized in Table 2.…”
Section: Multivariate Chemometric Methods: (Pls-2) and (Pcr)mentioning
confidence: 99%
“…The validation set is composed of 5 laboratory-prepared mixtures containing different proportions of AMP, SQX, and DVD (Table 1). In addition, the concentrations of AMP, SQX, and DVD in the veterinary formulation extract were calculated using the optimized PLS-2 or PCR calibration model after being recorded in the same specified lambda range [25][26][27][28][29][30][31][32][33].…”
Section: Pls-2 and Pcrmentioning