1988
DOI: 10.1007/bf00451596
|View full text |Cite
|
Sign up to set email alerts
|

Special problems of cementless fixation of total hip-joint endoprostheses with reference to the PM type

Abstract: The success of cement-free hip endoprosthetics is largely dependent on precise surgical techniques and primary stability of the anchorage, in which favorable biomechanical conditions as well as the quality of the stabilizing bone are of considerable importance. Information gathered from more than 1500 cementless hip-joint endoprosthesis implantations is presented with biomechanical solutions and indications regarding operating techniques, and a correlation between clinical symptoms and radiological signs of co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

1991
1991
2016
2016

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…It is also doubtful whether long-term press-fit fixation is achievable. In 1988 a new design of stem was introduced with a porous coating on the proximal third of the shaft (Refior et al 1988). No results have yet been published for this modification.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…It is also doubtful whether long-term press-fit fixation is achievable. In 1988 a new design of stem was introduced with a porous coating on the proximal third of the shaft (Refior et al 1988). No results have yet been published for this modification.…”
Section: Discussionmentioning
confidence: 99%
“…The stem has a drop-shaped macrostructure on its anterior and posterior surfaces. A good press-fit fixation of the distal two-thirds of the stem should be achieved after reaming the medullary canal (Refior et al 1988). We used a modular head of aluminium oxide ceramic (Biolox, Feldmühle Corporation); 83% of the stems had a collar (Fig.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The success of biological fixation is mainly dependent on meticulous surgical techniques and primary stability of the implant anchorage. 3 Biological fixation in which the prosthesis is directly fixed to the bone is considered as the best and ultimate fixation method. Absence of cement at the implant bone interface reduces the mechanically unstable interface.…”
Section: Introductionmentioning
confidence: 99%