2019
DOI: 10.1016/j.ultsonch.2018.09.029
|View full text |Cite
|
Sign up to set email alerts
|

Sonochemically recovered silver oxide nanoparticles from the wastewater of photo film processing units as an electrode material for supercapacitor and sensing of 2, 4, 6-trichlorophenol in agricultural soil samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 50 publications
(22 citation statements)
references
References 46 publications
0
21
0
Order By: Relevance
“…The peaks in the XRD pattern of Ag oxide sputter deposited on FTO (Figure b), located at 26.5°, 32.5°, 33.8, 38.1°, and 64.56° corresponds to Miller indices of (110), (111), (003), (200), and (220), respectively, matching with the cubic phase of Ag 2 O (JCPDS card number 76-1393). The peak at 44.3° matches with (132) crystal planes of AgO. Peak at 33.8° also matches with (202) crystal planes of AgO phase.…”
Section: Resultsmentioning
confidence: 99%
“…The peaks in the XRD pattern of Ag oxide sputter deposited on FTO (Figure b), located at 26.5°, 32.5°, 33.8, 38.1°, and 64.56° corresponds to Miller indices of (110), (111), (003), (200), and (220), respectively, matching with the cubic phase of Ag 2 O (JCPDS card number 76-1393). The peak at 44.3° matches with (132) crystal planes of AgO. Peak at 33.8° also matches with (202) crystal planes of AgO phase.…”
Section: Resultsmentioning
confidence: 99%
“…The mass of the active material (ZrW 2 O 8 NPs) was found to be 2 mg. The C sp values were calculated using Equations () and () for CV and GCD measurement respectively 30,31 . Also, the Electrochemical Impendence Spectroscopic analysis (EIS) of the as‐fabricated electrode was recorded in the frequency of 0.1 to 100 kHz at 10 mV AC. normalCsp=idvS.v.m normalCsp=I.tm.v where, idV, S, ∆ V , I , m , and ∆ t denote the integral area of one complete CV cycle, scan rate (mVs −1 ), potential window (V), discharge current (A), mass of the active material (mg), discharge time (s) respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The C sp values were calculated using Equations ( 1) and ( 2) for CV and GCD measurement respectively. 30,31 Also, the Electrochemical Impendence Spectroscopic analysis (EIS) of the asfabricated electrode was recorded in the frequency of 0.1 to 100 kHz at 10 mV AC.…”
Section: Electrode Fabrication and Electrochemical Measurementsmentioning
confidence: 99%
“…In general, the Nyquist plot is used to determine the important resistance phenomena such as solution resistance (R s ), charge transfer resistance (R ct ), and the equivalent series resistance (ESR) of the electrodes. 32,53 The intercept of the high-frequency semi-circle in the X-axis refers to R s , and the diameter of the circle in the highfrequency region refers to R ct . 43 The ESR value can be measured by combining the values of R s and R ct .…”
Section: Supercapacitor Measurement In Three-electrode Systemmentioning
confidence: 99%