2018
DOI: 10.1016/j.enbuild.2017.12.051
|View full text |Cite
|
Sign up to set email alerts
|

Smart ventilation energy and indoor air quality performance in residential buildings: A review

Abstract: 05CH11231, the CEC under the Califoarnia Energy Commission contract No. EPC-15-037 and Aereco SA under Contract No. FP00003428. The contribution of Cerema is funded by the French Ministries in charge of sustainable development, transports and urban planning, and by the Région Auvergne Rhône-Alpes.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
98
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 172 publications
(110 citation statements)
references
References 78 publications
0
98
0
1
Order By: Relevance
“…ASHRAE Standard 62 stipulates the minimal fresh outdoor airflow rate of 10 L/s per person to account for both human bio-effluents and contaminants related to building materials and furnishings [11, 25 30]. However, there are no justifications for the stipulated minimal amount of the fresh outdoor air whether it is adequate for indoor air quality [31]. An appropriate operation with a variable amount of the fresh outdoor air can generally provide more energy efficient indoor air quality compared with that of the constant fresh outdoor air.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…ASHRAE Standard 62 stipulates the minimal fresh outdoor airflow rate of 10 L/s per person to account for both human bio-effluents and contaminants related to building materials and furnishings [11, 25 30]. However, there are no justifications for the stipulated minimal amount of the fresh outdoor air whether it is adequate for indoor air quality [31]. An appropriate operation with a variable amount of the fresh outdoor air can generally provide more energy efficient indoor air quality compared with that of the constant fresh outdoor air.…”
Section: Introductionmentioning
confidence: 99%
“…A C C E P T E D ACCEPTED MANUSCRIPT 5 [31,32]. Thus, the operation optimization on the fresh outdoor air ratio of stratum ventilation is needed for energy efficiency improvement while providing satisfactory indoor air quality.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…With the improvement of living standards, people are increasingly aware of the importance and urgency of indoor air pollution control. Improving indoor air quality has become a trending topic worldwide [2,3] . In recent years, the continuous growth of the electronic information, aerospace, precision instrument, medical and health industries has greatly promoted the development of the clean room industry.…”
Section: Introductionmentioning
confidence: 99%
“…In the field of building HVAC, high energy saving potentials can be exploited in many ways. Scientific research focuses on measures on the building structure and insulation, different air routing concepts, the further development of the various components of an air conditioning system and, above all, the improvement of control technology [7][8][9][10]. Due to the volatile nature of wind and solar, energy demand requires more flexibility.…”
Section: Introduction and Problem Descriptionmentioning
confidence: 99%