2021
DOI: 10.1038/s41598-021-91898-6
|View full text |Cite
|
Sign up to set email alerts
|

Small flexible automated system for monitoring Caenorhabditis elegans lifespan based on active vision and image processing techniques

Abstract: Traditionally Caenorhabditis elegans lifespan assays are performed by manually inspecting nematodes with a dissection microscope, which involves daily counting of live/dead worms cultured in Petri plates for 21–25 days. This manual inspection requires the screening of hundreds of worms to ensure statistical robustness, and is therefore a time-consuming approach. In recent years, various automated artificial vision systems have been reported to increase the throughput, however they usually provide less accurate… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
29
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 14 publications
(29 citation statements)
references
References 46 publications
0
29
0
Order By: Relevance
“…Images were captured using the monitoring system developed in [ 29 ]. This system uses the active backlight illumination method proposed in [ 28 ], which consists of placing an RGB Raspberry Pi camera v1.3 (OmniVision OV5647, which has a resolution of 2592 × 1944 pixels, a pixel size of 1.4 × 1.4 μm, a view field of 53.50° × 41.41°, optical size of 1/4′′, and focal ratio of 2.9) in front of the lighting system (a 7′′ Raspberry Pi display 800 × 480 at a resolution at 60 fps, 24 bit RGB colour) and the inspected plate in between.…”
Section: Methodsmentioning
confidence: 99%
“…Images were captured using the monitoring system developed in [ 29 ]. This system uses the active backlight illumination method proposed in [ 28 ], which consists of placing an RGB Raspberry Pi camera v1.3 (OmniVision OV5647, which has a resolution of 2592 × 1944 pixels, a pixel size of 1.4 × 1.4 μm, a view field of 53.50° × 41.41°, optical size of 1/4′′, and focal ratio of 2.9) in front of the lighting system (a 7′′ Raspberry Pi display 800 × 480 at a resolution at 60 fps, 24 bit RGB colour) and the inspected plate in between.…”
Section: Methodsmentioning
confidence: 99%
“…The image acquisition process was performed using the capture system [ 37 ]. To use this system, first, a laboratory operator removed the plates from the incubator, then the plates were analyzed to find condensation on the covers, if so, they were removed, otherwise, the image sequence was captured.…”
Section: Methodsmentioning
confidence: 99%
“…To use this system, first, a laboratory operator removed the plates from the incubator, then the plates were analyzed to find condensation on the covers, if so, they were removed, otherwise, the image sequence was captured. The system [ 37 ] is automatic and captures an image every second. Escherichia coli ( E. coli ) strain OP50 was placed in the center of the plate to capture the worms inside the Petri dish and not scaling the edges or near them.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations