2009
DOI: 10.1093/jaoac/92.6.1807
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Spectrophotometric Determination of Benzoic Acid, Sorbic Acid, and Ascorbic Acid Using a Net Analyte Signal-Based Method

Abstract: The net analyte preprocessing/classical least-squares (NAP/CLS) method is a simple chemometric method that has been used for the simultaneous spectrophotometric determination of benzoic acid, sorbic acid, and ascorbic acid. The obtained results indicated that the performances of the NAP/CLS and partial least-squares methods were almost identical. The net analyte signal (NAS) concept was also used to calculate multivariate analytical figures of merit, such as LOD, selectivity, and sensitivity. Wavelength select… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Several methods were reported for the determination of ASC either per se or in pharmaceutical preparations and biological fluids. The recent methods include; spectrophotometry [4][5][6], spectrofluorimetry [7], voltammetry [8][9][10], HPLC [11][12][13][14], and capillary electrophoresis [15]. Salicylamide (SAL), 2-hydroxybenzamide (Figure 1b), is a salicylic acid derivative that has analgesic, anti-inflammatory, and antipyretic actions.…”
Section: Introductionmentioning
confidence: 99%
“…Several methods were reported for the determination of ASC either per se or in pharmaceutical preparations and biological fluids. The recent methods include; spectrophotometry [4][5][6], spectrofluorimetry [7], voltammetry [8][9][10], HPLC [11][12][13][14], and capillary electrophoresis [15]. Salicylamide (SAL), 2-hydroxybenzamide (Figure 1b), is a salicylic acid derivative that has analgesic, anti-inflammatory, and antipyretic actions.…”
Section: Introductionmentioning
confidence: 99%
“…[16][17][18] Net analyte signal calibration for a multivariate problem was originally described by Lorber. [19][20][21][22][23][24][25] Based on Lorber's definition the net analyte signal for any analyte based on spectroscopic methods is that part of the spectrum of the analyte that is orthogonal to the space spanned by the spectra of all constituents except the analyte, i.e., all interfering constituents (Fig. 1).…”
Section: Introductionmentioning
confidence: 99%
“…19 The NAS calculations are used both for estimation of the figures of merit of an analytical method and its performance including limit of detection, sensitivity and selectivity for each component 26 and for the construction of multivariate calibration models. [20][21][22][23][24][25][26] There are some reports on voltammetric determination of lead and tin by chemometrics methods 12,[27][28][29] and in this paper we develop a simple and new chemometrics method based on differential pulse polarography for simultaneous determination of Sn 2+ and Pb 2+ . With the DPP extremely overlapped peaks was obtained so they was determined by new method called net analyte signal standard addition method.…”
Section: Introductionmentioning
confidence: 99%