2015
DOI: 10.1016/j.talanta.2015.04.070
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous separation of chlorinated/brominated dioxins, polychlorinated biphenyls, polybrominated diphenyl ethers and their methoxylated derivatives from hydroxylated analogues on molecularly imprinted polymers prior to gas/liquid chromatography and mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
23
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 25 publications
(25 citation statements)
references
References 49 publications
(67 reference statements)
2
23
0
Order By: Relevance
“…The analytical procedure was based on a slightly modified procedure reported previously [46]. Briefly, 20 g of sample were spiked with 13 C 12 -labeled internal standards of PCB and PBDEs (50 pg each).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The analytical procedure was based on a slightly modified procedure reported previously [46]. Briefly, 20 g of sample were spiked with 13 C 12 -labeled internal standards of PCB and PBDEs (50 pg each).…”
Section: Methodsmentioning
confidence: 99%
“…The instrument setup was identical as reported previously [46]. Briefly, a Thermo-Finningan Trace GC Ultra gas chromatograph (Austin, TX, USA) connected via a heated transfer line with a Polaris Q low-resolution ion-trap mass spectrometer (Austin, TX, USA) was equipped with a Programmable Temperature Vaporizer (PTV) based injector, TriPlus Autosampler (Austin, TX, USA).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…[33,34] Pilehvar et al developed as ensing system for the detection of OH-PCBsi nh uman serum by employing an electrode modified with aptamer-immobilized carbon nanotubes. [31,32] Herein, we report the synthesis of aptamer-functionalized magnetic core-shell COF materials. Compared with electrochemical methods, LC-MS exhibits higher sensitivity and has become am ore powerful analytical technique for the determination of OH-PCBs.…”
Section: Introductionmentioning
confidence: 99%
“…[30,31] In humans and animals, PCBs can be metabolizedt oh ydroxylated PCBs (OH-PCBs) by cytochrome P450-mediated oxidation. [32] At present,t here are some reports on the determination of OH-PCBs in human blood and tissue samples. [33,34] Pilehvar et al developed as ensing system for the detection of OH-PCBsi nh uman serum by employing an electrode modified with aptamer-immobilized carbon nanotubes.…”
Section: Introductionmentioning
confidence: 99%