2016
DOI: 10.1016/j.bios.2016.04.103
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous photoelectrochemical and visualized immunoassay of β-human chorionic gonadotrophin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
15
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 40 publications
(15 citation statements)
references
References 39 publications
0
15
0
Order By: Relevance
“…GOx was bioconjugated onto the PbS QD/3D NiO-modified ITO electrode via the classic succinimide coupling (EDC-NHS) reaction between COOH groups on the surface of the TGA-capped PbS QDs and the NH 2 groups of GOx . The electrode was dipped into the solution containing 20 mg mL –1 EDC and 10 mg mL –1 NHS for 1 h at room temperature and then thoroughly rinsed with washing buffer.…”
Section: Methodsmentioning
confidence: 61%
“…GOx was bioconjugated onto the PbS QD/3D NiO-modified ITO electrode via the classic succinimide coupling (EDC-NHS) reaction between COOH groups on the surface of the TGA-capped PbS QDs and the NH 2 groups of GOx . The electrode was dipped into the solution containing 20 mg mL –1 EDC and 10 mg mL –1 NHS for 1 h at room temperature and then thoroughly rinsed with washing buffer.…”
Section: Methodsmentioning
confidence: 61%
“…As shown in Figure , a simultaneous color change from semitransparent white to dark purple could be directly observed by the naked eye, and a complementary colorimetric analyzer could thus be built, using the color intensity as an index. Using the photographs, the corresponding value could be quantified in the blue channel with the help of Adobe Photoshop software, as illustrated in Figure S8. , Incidentally, we had also studied the pore-size (ca. 280 nm) effect of the AAO film, and the results shown in Figure S9 demonstrated the suitability of the 90 nm sample.…”
Section: Resultsmentioning
confidence: 99%
“…Photoactive materials play critical roles in PEC systems; The PEC sensor output depends on the properties of these materials since they can influence the sensitivity and selectivity of the PEC sensor. Different photoactive materials, such as metal-based NPs [ 227 , 228 ], quantum dots (QDs) [ 229 ], carbon-based nanomaterials [ 230 ], layered nanomaterials [ 176 ], etc., have been studied in PEC application to fulfil specific demands. Furthermore, biological molecules, such as enzymes, antibodies, nucleic acids, etc., are also important for specific recognition in PEC biosensors and immunosensors.…”
Section: Application Of 2d Mos 2 -Based Nanocompos...mentioning
confidence: 99%