Simultaneous Determination of Docetaxel and Celecoxib in Porous Microparticles and Rat Plasma by Liquid-Liquid Extraction and HPLC with UV Detection: in vitro and in vivo Validation and Application

Abstract: Purpose: A simple, rapid, sensitive, and reliable HPLC method with UV detection was developed and validated for simultaneous quantitation of docetaxel and celecoxib and paclitaxel for dissolution characterization and pharmacokinetic studies. Methods: The HPLC assay was performed isocratically on a reversed-phase C18 μ-Bondapack column using a mobile phase of acetonitrile:water (45:55, v/v) at a flow rate of 1.2 mL/min, and the analytes were detected at 230 nm. Paclitaxel was used as an internal standard for an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(17 citation statements)
references
References 38 publications
(43 reference statements)
0
5
0
Order By: Relevance
“…The developed method achieved relatively low limits of [24]. HPLC coupled to MS increases sensitivity of the analysis, but the use of equipment requires skilled expertise to operate and is more expensive to run [9,25,26].…”
Section: Discussionmentioning
confidence: 99%
“…The developed method achieved relatively low limits of [24]. HPLC coupled to MS increases sensitivity of the analysis, but the use of equipment requires skilled expertise to operate and is more expensive to run [9,25,26].…”
Section: Discussionmentioning
confidence: 99%
“…Also, TFA has ion-pairing properties such that at low pHs (below the isoelectric pH of proteins), proteins are predominantly positively charged and are less hydrophobic to interact with the stationary phase, thus adding TFA to the mobile phase as an anionic counter ion, makes the protein more hydrophobic and interactive with the stationary phase, resulting in acceptable elution and retention time( 16 18 ). Moreover, the presence of TFA enhances the peak resolution and shapes as a result of minimizing the effect of metal impurities on peak shape in low-purity silica columns( 16 18 20 28 29 ). The volatility of ion-pairing reagents is an important issue because the risk of salt precipitation in the column is minimized (in comparison with phosphoric acid or buffers with acidic pH)( 16 17 18 19 20 ).…”
Section: Discussionmentioning
confidence: 99%
“…The analyte concentration that produced a signal-to-noise ratio of 3:1 was accepted as LOD. The LOQ was identified as the lowest concentration of the standard curve that could be quantified with acceptable accuracy, precision, and variability( 27 28 29 ).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations