2003
DOI: 10.1055/s-2003-41713
|View full text |Cite
|
Sign up to set email alerts
|

Simulation of Abdomen Sonography. Evaluation of a New Ultrasound Simulator

Abstract: In this first direct crossover comparison between real patient sonography and simulator based scanning we proved that the simulator we developed simulates the real patient examination reliably and reproducibly.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0
13

Year Published

2004
2004
2020
2020

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(33 citation statements)
references
References 14 publications
0
20
0
13
Order By: Relevance
“…Regarding clinical application of our findings, ultrasound simulation can serve as innovative method in education and training [3][4][5] and preparing staff before handling specialized procedures in UGRA. Here, we show that ultrasound of vessels and peripheral nerves can be reconstructed from 3D-UV with preservation at highresolution ultrasonographic appearance of nervous echo texture [6] by means of a simple electromagnetically tracking system [5]. Such 3D-UV are well suited to study sonoanatomy, learn handling and movement of ultrasound probe, plane interpretation for UGRA and of sonoanatomic landmark structures for specific block techniques.…”
Section: Discussionmentioning
confidence: 91%
See 2 more Smart Citations
“…Regarding clinical application of our findings, ultrasound simulation can serve as innovative method in education and training [3][4][5] and preparing staff before handling specialized procedures in UGRA. Here, we show that ultrasound of vessels and peripheral nerves can be reconstructed from 3D-UV with preservation at highresolution ultrasonographic appearance of nervous echo texture [6] by means of a simple electromagnetically tracking system [5]. Such 3D-UV are well suited to study sonoanatomy, learn handling and movement of ultrasound probe, plane interpretation for UGRA and of sonoanatomic landmark structures for specific block techniques.…”
Section: Discussionmentioning
confidence: 91%
“…Ultrasound simulator and recording system A free-hand recording system as part of an ultrasound simulation system (Ultrasound simulator Reslice, registered trademark by Schallware GmbH, Berlin, Germany, http://www.schallware.de) [5] was coupled to a high-end ultrasound device (Vivid-i, registered trademark by GE Healthcare Ultrasound, Solingen, Germany) with a 12 MHz linear probe (12L). The free-hand recording system consists of a PC with Ubuntu software platform (Linux-based public license, non-commercial software, version 7.10, http://www.ubuntu.com), an electromagnetic tracking system, a mannequin and a probe dummy with localization transmitter, and also consists of a PC with recording software (Schallware Acquisition 2007, Fa.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…B. durch Darstellung einer definierten Schnittebene oder Markierung eines pathologischen Befundes -in Echtzeit ausgewertet werden kön-nen und so den Erfolg des Training unmittelbar sichtbar werden lassen können [10]. Großes Interesse besteht aus diesem Grund auch auf anderen Gebieten der Medizin [11,12,13,14]. …”
Section: Ausblickunclassified
“…Existing methods for real-time simulation of ultrasound such as [2,3,4] are based on acquisition of actual ultrasound images and creating a compounded 3D volume of the region of interest. The volume is then sliced at run-time based on the position of a virtual probe.…”
Section: Introductionmentioning
confidence: 99%