1999
DOI: 10.1002/(sici)1099-0534(1999)11:1<29::aid-cmr2>3.3.co;2-d
|Get access via publisher |Summarize |Cite
Signal Intensities and T1 Calculations in Multiple‐Echo Sequences with Imperfect Pulses
Abstract: Formulas are derived for longitudinal magnetization in multiple‐echo inversion recovery (IR), saturation recovery, and progressive saturation pulse sequences with imperfect pulses. The effects of imperfect pulses on the signal intensities and on the calculated T1 relaxation times are discussed. Relaxation data from all three methods can be fitted with an equation of the form: Signal intensity=[a+b exp(−TX/T1)]/[1+c exp(−TX/T1)], where TX is a variable delay time and the values of T1, a, b, and c are adjusted t…
Search citation statements
Paper Sections
Select...
24
8
6
1
Citation Types
0
28
0
0
Year Published
1999
2022
Publication Types
Select...
32
2
Relationship
1
33
Authors
Journals
Cited by 34 publications
(28 citation statements)
References 56 publications
0
28
0
0
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…This study indicates a relationship between physical exercise and cartilage structure, as shown by a lower contrast distribution in exercising individuals compared to sedentary individuals. A correlation between contrast agent distribution and GAG has previously been established both in vitro and in vivo, suggesting that the low contrast distribution in the exercising subjects corresponds to a high GAG content (24, 26–28, 33). Despite the limitations of a cross‐sectional study, this is the first study to provide evidence for an adaptive capacity of human cartilage.…”
Section: Discussion
mentioning
confidence: 85%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…This study indicates a relationship between physical exercise and cartilage structure, as shown by a lower contrast distribution in exercising individuals compared to sedentary individuals. A correlation between contrast agent distribution and GAG has previously been established both in vitro and in vivo, suggesting that the low contrast distribution in the exercising subjects corresponds to a high GAG content (24, 26–28, 33). Despite the limitations of a cross‐sectional study, this is the first study to provide evidence for an adaptive capacity of human cartilage.…”
Section: Discussion
mentioning
confidence: 85%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The suitability of FSE sequences (33) and spoiled gradient echo sequences (32) for accurate T1 measurement has been demonstrated in the literature. However, much higher resolution was required in our studies, thus necessitating further evaluation of T1 accuracy.…”
Section: Results
mentioning
confidence: 99%
“…For 3D‐SPGR, SNR was fairly high (25–40). However, with short TR the signal difference for different flip angles is very small; thus SPGR T1 measurements showed significant variability (30).…”
Section: Results
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…That being said, Kingsley demonstrated that the estimated T 1 in phantoms remained constant using an IR‐prepared fast/turbo spin‐echo sequence with up to 16 echoes; this suggests that stimulated echoes may not be a significant problem after all.…”
Section: Discussion
mentioning
confidence: 98%
