Abstract: Albeit a similar safety profile with low clinical event rates, transcatheter aortic valve replacement with the ACURATE neo valve resulted in lower transvalvular gradients and consequently less prosthesis-patient mismatch compared with the SAPIEN 3 in patients with small annulus. These results emphasize the need of careful prosthesis selection in each individual patient.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

12
53
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 85 publications
(65 citation statements)
references
References 29 publications
12
53
0
Order By: Relevance
“…Of those, 52 were further excluded because they were not pertinent to the design of the meta-analysis or did not meet the explicit inclusion criteria. One RCT [14] and five observational studies [15][16][17][18][19] enrolling the total of 2818 patients were eventually included in the analysis. Potential sources of the studies' bias were analyzed with the use of components recommended by the Cochrane Collaboration and ROBINS-I tool, and the results are enclosed as Table A2.…”
Section: Study Selection and Biasmentioning
confidence: 99%
See 4 more Smart Citations
“…Of those, 52 were further excluded because they were not pertinent to the design of the meta-analysis or did not meet the explicit inclusion criteria. One RCT [14] and five observational studies [15][16][17][18][19] enrolling the total of 2818 patients were eventually included in the analysis. Potential sources of the studies' bias were analyzed with the use of components recommended by the Cochrane Collaboration and ROBINS-I tool, and the results are enclosed as Table A2.…”
Section: Study Selection and Biasmentioning
confidence: 99%
“…Aortic valve baseline echo-parameters, i.e., mean trans-aortic gradient were comparable: 43.4 ± 15.8 vs. 43.6 ± 15.5 mmHg (P = 0.861) in ACURATE neo and SAPIEN 3, respectively (Figure 2), although the aortic annulus plane area were on average 4 mm 2 smaller in the ACURATE neo recipients 439.7 ± 62.4 vs. 446.7 ± 76.3; P = 0.037 as compared to SAPIEN 3. Transfemoral access was mostly widely employed during TAVR procedure; in five studies, it was used exclusively [14,[16][17][18][19]. Barth et al [15] included both transfemoral and transapical access in 75.7% vs. 24.3% and 74.5% vs. 25.5% for ACURATE neo and SAPIEN 3, respectively.…”
Section: Patients Characteristicmentioning
confidence: 99%
See 3 more Smart Citations