2018
DOI: 10.1016/j.saa.2018.04.068
|View full text |Cite
|
Sign up to set email alerts
|

Sequential injection analysis for the determination of fluoroquinolone antibacterial drug residues by using eosin Y as complexing agent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…For a sequential injection system, Chaiyasing et al 24 reported on the use of a SIA method for the rapid and sensitive determination of fluoroquinolone residues, including norfloxacin, ciprofloxacin and enrofloxacin, in fish samples using eosin Y as a reagent. The last is that Alarfaj et al 25 proposed a new sequential chemiluminescence strategy for monitoring the caffeine content in soft and energy drinks.…”
Section: Application Of Flow-based System For Quality Control and Foo...mentioning
confidence: 99%
“…For a sequential injection system, Chaiyasing et al 24 reported on the use of a SIA method for the rapid and sensitive determination of fluoroquinolone residues, including norfloxacin, ciprofloxacin and enrofloxacin, in fish samples using eosin Y as a reagent. The last is that Alarfaj et al 25 proposed a new sequential chemiluminescence strategy for monitoring the caffeine content in soft and energy drinks.…”
Section: Application Of Flow-based System For Quality Control and Foo...mentioning
confidence: 99%
“…For instance, the continued intake of antibiotics by humans can lead to other human health problems such as weakened immunity, allergic reactions, hereditary diseases, and the occurrence of cancer. Until now, a number of methods have been developed for the determination of NFX residues, such as liquid chromatography with fluorescent detection, 3 sequential injection analysis, 4 high-performance liquid chromatography, 5 capillary electrophoresis, 6 and electrochemical analysis. 7 Among them, liquid chromatography with fluorescent detection can achieve good sensitivity, but the pre-treatment step required is time-consuming and the equipment is expensive.…”
Section: Introductionmentioning
confidence: 99%
“…This technique relies on the interaction between the analyte and a colorproducing reagent or indicator. There are various colorimetric reactions used to detect drugs such as metal-ligand complexation [15][16][17], redox reaction [18,19], charge transfer complexation [20][21][22], ion-pair complexation [13,[23][24][25][26], and azo dye formation [27,28,30] as shown in Table 2.4. Among them, dye binding reagents are attractive alternative reagents for colorimetric assay in response to concerns over the toxicity of metal ions and the instability of oxidizing agents.…”
Section: Colorimetric Reactions For Norfloxacin and Ceftazidime Deter...mentioning
confidence: 99%
“…Based on norfloxacin structure as zwitterion, it could form ion-pair complexes with cationic or anionic dyes under controlled solution pH. Various reagents for dye binding, including Congo red [24], bromophenol blue [13], and Eosin Y [23], have been employed for norfloxacin determination.…”
Section: Colorimetric Reactions For Norfloxacin and Ceftazidime Deter...mentioning
confidence: 99%
See 1 more Smart Citation