2020
DOI: 10.1002/elan.201900670
|View full text |Cite
|
Sign up to set email alerts
|

Sensor Platform with a Custom‐tailored Aptamer for Diagnosis of Synthetic Cannabinoids

Abstract: Synthetic cannabinoids (SCs) are the large group of abused drugs and detection of them is still a challenge. Hence, new methods for analysis of SCs are being investigated. We aimed to develop a novel system for selective analysis of SCs. First, various custom‐tailored aptamers against the target SCs were selected through GO‐SELEX process. Toggling between different SC analytes during successive rounds of selection was performed to generate cross‐reactive aptamers. Then, the amino‐capped aptamers were synthesiz… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 53 publications
0
7
0
Order By: Relevance
“…6 Peaks were observed in C 1s spectra. Peak at 284.17 eV was shown pure graphitic sites [36], while peak at 284.78 eV was shown C−C or C=C binding [37]. Peak at 285.3 eV was indicated the presence of hydrocarbons in PBA [38].…”
Section: Resultsmentioning
confidence: 99%
“…6 Peaks were observed in C 1s spectra. Peak at 284.17 eV was shown pure graphitic sites [36], while peak at 284.78 eV was shown C−C or C=C binding [37]. Peak at 285.3 eV was indicated the presence of hydrocarbons in PBA [38].…”
Section: Resultsmentioning
confidence: 99%
“…As shown in Figure 2A, after adding GO and the target in the incubation system at the ratio of 5000:1, free target still existed in the solution. Based on the previous report [21] and cost, 500:1 was used as the mass ratio of GO/target. GO-SELEX was suitable for screening the aptamers of targets which cannot be absorbed by GO.…”
Section: Screening Of Thiamethoxam Aptamersmentioning
confidence: 99%
“…Since different lengths of ssDNA show different binding kinetics on the GO surface [24], the GO/ssDNA mass ratio was optimized before GO-SELEX experiments, enabling GO to fully adsorb ssDNA. Commonly, the GO/ssDNA quality ratio was between 500:1 and 1000:1 [21,25], allowing the ssDNA concentration to reach the baseline level. In Figure 2B, the nucleic acid concentration was seen to decrease with the increase of GO/ssDNA, and at the mass ratio of 500:1, the DNA content in the solution reached the first equilibrium point, indicating that this concentration reached the baseline level, consistent with previous studies [21].…”
Section: Screening Of Thiamethoxam Aptamersmentioning
confidence: 99%
See 2 more Smart Citations