2003
DOI: 10.1016/s0731-7085(03)00169-9
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive determination of buprenorphine and its N-dealkylated metabolite norbuprenorphine in human plasma by liquid chromatography coupled to tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
48
0

Year Published

2005
2005
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(51 citation statements)
references
References 37 publications
2
48
0
Order By: Relevance
“…25 Lower LOQs for BUP were achieved in procedures by determining fewer analytes, and therefore allowing for longer dwell times, 21,23,25,26,56,57 by applying a stronger ionization using an APCI interface (atmospheric pressure chemical ionization) 21,57 or by using equivocal MRM transitions with the same parent and daughter ion masses of BUP. 19,23,25 Other groups prefer GC/MS procedures for the analysis of BUP. 14,22 An important aim of the present work was to achieve good chromatographic separation of HYD and MOR, as well as the separation of M3G and M6G.…”
Section: Discussionmentioning
confidence: 99%
“…25 Lower LOQs for BUP were achieved in procedures by determining fewer analytes, and therefore allowing for longer dwell times, 21,23,25,26,56,57 by applying a stronger ionization using an APCI interface (atmospheric pressure chemical ionization) 21,57 or by using equivocal MRM transitions with the same parent and daughter ion masses of BUP. 19,23,25 Other groups prefer GC/MS procedures for the analysis of BUP. 14,22 An important aim of the present work was to achieve good chromatographic separation of HYD and MOR, as well as the separation of M3G and M6G.…”
Section: Discussionmentioning
confidence: 99%
“…5 and liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS). 6 method including BUP, NBUP and buprenorphine-3-ˇ-Dglucuronide (BUP-3-G) in human plasma was developed using LC/ESI-MS/MS. 7 Ceccato et al 6 and Polettini and Huestis 7 quantified BUP and NBUP using the transition of the precursor mass to the precursor mass in quadrupole three of the triple-quadrupole mass spectrometer.…”
Section: Introductionmentioning
confidence: 99%
“…Full validation and application were well performed in the study; however, according to this study, naloxone with LLOQ of 0.1 ng mL -1 is not sensitive enough to enable pharmacokinetics profiling since it has low bioavailability. Moreover, a low dose of BUP administered sublingually resulted in a range of BUP hard to detect in the plasma [25,26]. Many limitations due to biological samples still remain.…”
Section: Introductionmentioning
confidence: 99%