2008
DOI: 10.1061/(asce)0733-9445(2008)134:1(132)
|View full text |Cite
|
Sign up to set email alerts
|

Seismic Response Evaluation of Posttensioned Precast Concrete Frames with Friction Dampers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 81 publications
(30 citation statements)
references
References 10 publications
1
22
0
Order By: Relevance
“…Clark et al (1973) presented test results for a static load control FD intended to limit the effect of differential settlement that occurs at foundations. 13 Other researchers used FDs for energy dissipation in various types of earthquake-resistant structures (ie bridge structures, 14 precast concrete structures, [15][16][17][18][19] steel braced frames, 20-30 steel moment resisting frames, 31 self-centering moment resisting frames, [32][33][34][35][36][37] and rocking timber shear walls 38 ). Friction dampers [39][40][41][42][43] and self-centering braces with friction-based energy dissipation [44][45][46][47] have been developed and tested.…”
Section: Friction Devicementioning
confidence: 99%
“…Clark et al (1973) presented test results for a static load control FD intended to limit the effect of differential settlement that occurs at foundations. 13 Other researchers used FDs for energy dissipation in various types of earthquake-resistant structures (ie bridge structures, 14 precast concrete structures, [15][16][17][18][19] steel braced frames, 20-30 steel moment resisting frames, 31 self-centering moment resisting frames, [32][33][34][35][36][37] and rocking timber shear walls 38 ). Friction dampers [39][40][41][42][43] and self-centering braces with friction-based energy dissipation [44][45][46][47] have been developed and tested.…”
Section: Friction Devicementioning
confidence: 99%
“…The effectiveness of the friction dampers has been verified by many researchers. Morgen and Kurama (2008) carried out a seismic response evaluation tests of unbonded posttensioned precast concrete moment frames with friction dampers at selected beam ends. Mualla et al (2010) developed a rotational friction damper which can produce maximum friction force as high as 5000 kN (Table 2).…”
Section: Addition Of Rotational Friction Dampersmentioning
confidence: 99%
“…Energy dissipation is supplied at the beam-to-column joint through a variety of mechanisms such as unbonded mild reinforcing steel [64], friction damping elements [79] and other devices.…”
Section: Concrete Self-centering Moment Resisting Framesmentioning
confidence: 99%