Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2001
2001
2016
2016

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 9 publications
0
7
0
1
Order By: Relevance
“…Although physically active subjects may develop maximal compression forces in the knee joint that exceed full weight bearing conditions up to factor seven [30], from the clinical point of view full weight bearing is not prescribed at least in the early rehabilitation stages. Furthermore, 842 N were assumed as screw extraction strength based on the results of Hearn et al [21]. The screw extraction strength required for screw failure may depend on the biomechanical test settings.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although physically active subjects may develop maximal compression forces in the knee joint that exceed full weight bearing conditions up to factor seven [30], from the clinical point of view full weight bearing is not prescribed at least in the early rehabilitation stages. Furthermore, 842 N were assumed as screw extraction strength based on the results of Hearn et al [21]. The screw extraction strength required for screw failure may depend on the biomechanical test settings.…”
Section: Discussionmentioning
confidence: 99%
“…The value was derived from the 842 N as the screw extraction strength resulting in a screw fixation failure [21] applied to a 50 mm long screw (the maximum screw length modelled) with a diameter of 4.5 mm (the average of 4 and 5 mm modelled screws).…”
Section: Methodsmentioning
confidence: 99%
“…Calculating the paired-design sample size reduction factor (λp) based on the sample sized for unpaired and paired study designs for contralateral premolars is given by the following equation [333,337]:…”
Section: Faculty Of Dentistry | University Of Oslo | 2018mentioning
confidence: 99%
“…It has been demonstrated that matched experimental designs using human bone can have the same statistical power as unmatched designs. Matched pair experiments require between 11.5 and 28.4% of the number of unmatched bone specimens, depending upon the anatomical location of the tests (6). The use of unmatched bones would require between 82 to 90 ML trials and 41 to 45 each of the CC trials, or 15 (unmatched) pairs, to achieve the same statistical power achieved in this study.…”
Section: Discussionmentioning
confidence: 76%