2017
DOI: 10.1007/s00261-017-1267-4
|View full text |Cite
|
Sign up to set email alerts
|

Safety and efficacy of transcatheter embolization with Glubran®2 cyanoacrylate glue for acute arterial bleeding: a single-center experience with 104 patients

Abstract: NBCA-MS Glubran2 TAE is a fast, effective, and safe treatment for acute arterial bleeding whatever the bleeding site.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
36
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 39 publications
(49 citation statements)
references
References 39 publications
2
36
0
Order By: Relevance
“…Since adequate control could not be obtained and superselective catheterization showed multiple tortuous vessels feeding the diseased portion of the right upper lung distal to the coils, a decision was made to embolize with a liquid embolic agent. While other liquid embolic agents such as NBCA are increasingly being used in BAE (Woo et al 2013;Abdulmalak et al 2018) with successful results, we chose Onyx for embolization through the Scepter balloon. The inflated Scepter balloon created a "plug" and allowed for more controlled and deeper penetration into distal bronchial artery with indwelling coils without the need of robust forward flow, which is required in the much harder to control NBCA (Urbano et al 2014).…”
Section: Discussionmentioning
confidence: 99%
“…Since adequate control could not be obtained and superselective catheterization showed multiple tortuous vessels feeding the diseased portion of the right upper lung distal to the coils, a decision was made to embolize with a liquid embolic agent. While other liquid embolic agents such as NBCA are increasingly being used in BAE (Woo et al 2013;Abdulmalak et al 2018) with successful results, we chose Onyx for embolization through the Scepter balloon. The inflated Scepter balloon created a "plug" and allowed for more controlled and deeper penetration into distal bronchial artery with indwelling coils without the need of robust forward flow, which is required in the much harder to control NBCA (Urbano et al 2014).…”
Section: Discussionmentioning
confidence: 99%
“…For this purpose, it is needed to use a higher ratio than usual (1:3) in order to delay the polymerization of the glue in contact with blood and allow the mixture reach the distal parenchymal vascular bed before polymerization (15). Cyanoacrylate is more viscous than microparticles (24)(25)(26)(27). The possibility of significant ischemic complications is therefore unlikely.…”
Section: Discussionmentioning
confidence: 99%
“…The use of glue is widespread in many surgical fields, as bariatric, colorectal and vascular surgery [ [4] , [5] , [6] , [7] ].…”
Section: Discussionmentioning
confidence: 99%