2017
DOI: 10.1016/j.ajo.2016.12.003
|View full text |Cite
|
Sign up to set email alerts
|

Repeatability and Agreement of Orbscan II, Pentacam HR, and Galilei Tomography Systems in Corneas With Keratoconus

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
47
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 87 publications
(61 citation statements)
references
References 27 publications
3
47
0
2
Order By: Relevance
“…Galilei and Pentacam in keratoconic eyes and observed that Orbscan II has the least repeatable measurements. Furthermore there was no significant difference between Pentacam and Galilei [11]. Another study that showed no agreement between corneal diameters measured by Galilei.…”
Section: Discussionmentioning
confidence: 90%
See 1 more Smart Citation
“…Galilei and Pentacam in keratoconic eyes and observed that Orbscan II has the least repeatable measurements. Furthermore there was no significant difference between Pentacam and Galilei [11]. Another study that showed no agreement between corneal diameters measured by Galilei.…”
Section: Discussionmentioning
confidence: 90%
“…we compared the repeatability and interoperator reproducibility of a new corneal topographer module of Revo NX SD-OCT with Galilei G6 Schimpflug camera and Casia 2 SS-OCT in normal eyes. As it was concluded in many previous studies the measurements from two keratometric systems cannot be used interchangeably [3,[10][11][12] There are two types of devices capable of measuring anterior and posterior keratometry: OCT based systems and Scheimpflug camera. Some OCT systems use swept-source technology featuring lower resolution but faster acquisition rate [13].…”
Section: Discussionmentioning
confidence: 99%
“…[4] At present, various methods are used for the CCT measurement, such as ultrasound pachymetry (USP), Scheimflug photography, optical coherence tomography and so on. [5][6][7][8][9] Most often, USP is regarded as the gold-standard technique for measuring CCT. [10][11][12] Many studies have evaluated the precision (repeatability and reproducibility) and agreement of CCT measurements among the abovementioned devices.…”
Section: Introductionmentioning
confidence: 99%
“…[10][11][12] Many studies have evaluated the precision (repeatability and reproducibility) and agreement of CCT measurements among the abovementioned devices. [7,8,[11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26] The results, however, have not always been consistent.…”
Section: Introductionmentioning
confidence: 99%
“…Several studies have demonstrated better measurement precision in healthy eyes 10,11 than keratoconic eyes 1214 , for various clinical parameters and different imaging devices. Previously reported repeatability and reproducibilty data of keratoconic eyes have been inconsistent and vary considerably among different studies and devices.…”
Section: Introductionmentioning
confidence: 99%