2010 12th Electronics Packaging Technology Conference 2010
DOI: 10.1109/eptc.2010.5702660
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of palladium coated copper wire

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
9
0

Year Published

2011
2011
2014
2014

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 3 publications
2
9
0
Order By: Relevance
“…Considering actual time length of humidity reliability test, Pd is absolute barrier layer to prevent Cu and Al diffusion and then no diffusion means no easily-corroded Cu rich IMC creation. The other experimental results showed thinner IMC growth with Cu-Pd wire than Cu wire [4,10] and more Pd at the surface of FAB showed less growth of Cu/Al IMC [14], which are consistent with our simulation results. Although these experimental IMC growth measurements was done at 175degC HTSL condition, this Pd barrier effect for Cu an Al diffusion should be still valid even at higher temperature.…”
Section: Case 2 Pd Is Only At Surface Case 2-1 Pd Could Behave Barrsupporting
confidence: 95%
See 1 more Smart Citation
“…Considering actual time length of humidity reliability test, Pd is absolute barrier layer to prevent Cu and Al diffusion and then no diffusion means no easily-corroded Cu rich IMC creation. The other experimental results showed thinner IMC growth with Cu-Pd wire than Cu wire [4,10] and more Pd at the surface of FAB showed less growth of Cu/Al IMC [14], which are consistent with our simulation results. Although these experimental IMC growth measurements was done at 175degC HTSL condition, this Pd barrier effect for Cu an Al diffusion should be still valid even at higher temperature.…”
Section: Case 2 Pd Is Only At Surface Case 2-1 Pd Could Behave Barrsupporting
confidence: 95%
“…[1,4,8,10,11,12,13] The Pd distribution in FAB could be decided by Pd-Cu type from different wire supplier and bonding condition. [12,14,15] The mechanism of Pd-Cu wire humidity reliability improvement over bare Cu wire needs to discussed case by case.…”
Section: Fig 10 Hast Results Comparison Between Cu and Pd-cumentioning
confidence: 99%
“…Earlier studies [5] have shown that the first bond process responses of shear/area and ball diameter of PdCu and bare Cu wire are nearly the same for the same bonding parameters. However, the PdCu free-air ball is harder [4,8] and appears to cause more pad damage [5]. Peels, lifts and craters are more likely.…”
Section: Introductionmentioning
confidence: 99%
“…The shear strength increased more than 30% after subjected to isothermal aging at 175°C for 336 hours, but subsequently remained unchanged up till 1008 hours, similar trend to the previous studies performed on Cu wire bonding. 13,14 The initial shear mode for both bare Cu and insulated Cu was through a Al bond pad. However, as the isothermal aging hours increased, the shear mode was through Cu ball bond.…”
Section: Ball Shear and Wire Pull Strengthmentioning
confidence: 99%