2019
DOI: 10.2319/082018-612.1
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of 3D dental and skeletal landmarks on CBCT images

Abstract: Objectives: To quantify reliability of three-dimensional skeletal landmarks and a comprehensive set of dental landmarks in cone-beam computed tomography (CBCT) and to determine the shapes of envelope of error. Materials and Methods: Three judges located 31 skeletal landmarks and 60 dental landmarks on the pre- and posttreatment CBCT images of 22 patients. Landmark error was determined by calculating the distance of deviation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(21 citation statements)
references
References 14 publications
(26 reference statements)
0
21
0
Order By: Relevance
“…19,20 In this study, in order to reduce errors in landmark identification, a CBCT-based dentofacial image was chosen as reference standard. 21 Five landmarks were digitized on the original digital dental model before the registration procedure. Subsequently, the original dental model was duplicated to the reference standard to avoid error from landmark identification.…”
Section: Discussionmentioning
confidence: 99%
“…19,20 In this study, in order to reduce errors in landmark identification, a CBCT-based dentofacial image was chosen as reference standard. 21 Five landmarks were digitized on the original digital dental model before the registration procedure. Subsequently, the original dental model was duplicated to the reference standard to avoid error from landmark identification.…”
Section: Discussionmentioning
confidence: 99%
“…The geometric accuracy of the 3Shape R700 scanner was verified to be 0.02 mm. Previous studies have proven that landmarking dental 3D models is reliable [11] and the measurements on 3D surfaces have excellent accuracy [12].…”
Section: Methodsmentioning
confidence: 99%
“…A radical turnaround in clinical procedures and in the way of technical preparation of implantation using CAD/CAM methods is worked. They include the authors' own methods [3,[206][207][208]210,212,223,244,245] regarding data acquisition by means of cone-beam computed tomography (CBCT) in planning and performing implant prosthetic treatment and also in endodontics and orthodontics [408][409][410][411][412][413][414][415][416][417][418][419][420][421][422][423][424][425][426][427].…”
Section: General Characteristics Of the Dentistry 40 Stage Of Designmentioning
confidence: 99%