2021
DOI: 10.1016/j.jbiomech.2021.110393
|View full text |Cite
|
Sign up to set email alerts
|

Refining a numerical model for device-induced thrombosis and investigating the effects of non-Newtonian blood models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
23
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(24 citation statements)
references
References 26 publications
1
23
0
Order By: Relevance
“…Data from the latest BSF experiment which used human blood shows the thrombi is a triangular ramp shape ( Yang et al, 2020 ). While a quasi-triangular slope shape is observed in our simulation results, which is similar to the previous computational report ( Yang et al, 2021 ). There may be three reasons for the difference in thrombus shape.…”
Section: Discussionsupporting
confidence: 92%
See 1 more Smart Citation
“…Data from the latest BSF experiment which used human blood shows the thrombi is a triangular ramp shape ( Yang et al, 2020 ). While a quasi-triangular slope shape is observed in our simulation results, which is similar to the previous computational report ( Yang et al, 2021 ). There may be three reasons for the difference in thrombus shape.…”
Section: Discussionsupporting
confidence: 92%
“…Recently, Yang et al (2020) provided experimental data for device-induced thrombosis using bovine and human blood in the same backward-facing step model as Taylor et al (2014) . Besides, Yang et al (2021) analyzed the thrombosis formation for non-Newtonian blood by developing the device-induced thrombosis model proposed by Taylor et al (2016b) . These studies have laid a good foundation for macroscopic thrombosis research.…”
Section: Introductionmentioning
confidence: 99%
“…The parameter values used in the various equations of the Taylor model are given in Table 1 of Taylor et al 12 Taylor et al 12 also performed blood-loop experiments to train and validate the derived model. Yang et al 13 later made modifications to the Taylor 12 model, in particular incorporating a different model for chemical platelet activation, since the Taylor 12 model never reached high enough levels of ADP to lead to chemical platelet activation. The Yang et al 13 chemical activation model is used in the current iteration of the thrombosis model, and is given in Equation (11).…”
Section: Taylor Model and Modifications From Yang Et Almentioning
confidence: 99%
“…Yang et al 13 later made modifications to the Taylor 12 model, in particular incorporating a different model for chemical platelet activation, since the Taylor 12 model never reached high enough levels of ADP to lead to chemical platelet activation. The Yang et al 13 chemical activation model is used in the current iteration of the thrombosis model, and is given in Equation (11). Yang et al 13 also investigated the use on non-Newtonian viscosity models, which are not incorporated into the current study.…”
Section: Taylor Model and Modifications From Yang Et Almentioning
confidence: 99%
See 1 more Smart Citation