2002
DOI: 10.1016/s1010-7940(02)00372-x
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation

Abstract: The MECC system is suitable to maintain total extracorporeal circulation and demonstrates a lower inflammatory reaction when compared to standard CPB.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

23
229
0
15

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 295 publications
(280 citation statements)
references
References 24 publications
23
229
0
15
Order By: Relevance
“…A substantial feature of all 'mini-CPB' systems is the lack of contact of the blood with the air due to the absence of the cardiotomy reservoir. The presence of barriers separating the blood from the air and decreasing the surface of contact of artificial materials with the blood gives measurable benefits, such as reduction in the incidence of the systemic inflammatory response syndrome (SIRS), although SIRS itself occurs almost always, with a variable degree of severity [1,2]. 'Mini-CPB' significantly decreases the incidence of early inflammatory response, which was confirmed in a randomised trial by Kiaii et al [3] and in other studies [1,4].…”
Section: Discussionmentioning
confidence: 89%
“…A substantial feature of all 'mini-CPB' systems is the lack of contact of the blood with the air due to the absence of the cardiotomy reservoir. The presence of barriers separating the blood from the air and decreasing the surface of contact of artificial materials with the blood gives measurable benefits, such as reduction in the incidence of the systemic inflammatory response syndrome (SIRS), although SIRS itself occurs almost always, with a variable degree of severity [1,2]. 'Mini-CPB' significantly decreases the incidence of early inflammatory response, which was confirmed in a randomised trial by Kiaii et al [3] and in other studies [1,4].…”
Section: Discussionmentioning
confidence: 89%
“…In piglet experimental models, an exhaustion of cerebral energy reservoirs was demonstrated during the course of profound hypothemic circulatory arrest at a core temperature of 18°C and rewarming (18). Release of S100 protein showed higher values in patients undergoing standard CPB than after minimal extracorporeal circulation (19). Prolonged mechanical ventilation and increased the number of bypassed coronary arteries also contributed to impaired verbal memory and deteriorated cerebral blood perfusion (16).…”
Section: Discussionmentioning
confidence: 99%
“…The heparin pre-treatment of the circuit minimizes the systemic heparinization dose requirements (usually half dose of conventional ECC: 150IU/Kg instead of 300IU/Kg) (Curtis et al 2010;Formica et al 2009, Puheler et al 2009Beghi et. 2006) and provides biocompatibility for blood cells (Koivisto et al 2010;Remadi et al 2007;Remadi et al 2004;Fromes et al 2002;) Fig. 1.…”
Section: Anatomy Of the Miniaturized Extracorporeal Circulation Systemmentioning
confidence: 99%
“…These characteristics lead to a circuit prime volume smaller than standard ECC, ranging between 200-650 ml for the MECC against 1200-1600 ml for the standard ECC (Formica et al 2009Remady et al 2006). The combination of short length tubing, heparin pre-treatment, small size tubing and absence of a venous reservoir, leads to a significant reduction of hemodilution with as well as a reduction in clotting factor consumption ad triggering of SIRS (Vohra et al 2009;Ohata et al 2007;Wippermann et al 2005;Fromes et al 2002). The blood pump included in the circuit is usually a centrifugal pump.…”
Section: Anatomy Of the Miniaturized Extracorporeal Circulation Systemmentioning
confidence: 99%