1997
DOI: 10.1016/s0894-7317(97)80029-6
|View full text |Cite
|
Sign up to set email alerts
|

Reduced forward output states affect the left ventricular opacification of intravenously administered albunex

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0
2

Year Published

1998
1998
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 15 publications
1
5
0
2
Order By: Relevance
“…Air-lled microspheres, such as constitute Albunex, are susceptible to decreases in size due to diffusion and destruction by ventricular systolic pressure and acoustic pressure during fundamen-tal ultrasound imaging. 17,18 Signi cantly greater duration of contrast has been achieved with per uoropropane-lled albumin microspheres (Optison), 6 as well as with other microbubble preparations that contain uorocarbon gases, which have low solubility and diffusivity and are more pressure resistant. 1 9,20 Studies have shown that such agents are more effective than Albunex for improving delineation of endocardial border.…”
Section: Discussionmentioning
confidence: 99%
“…Air-lled microspheres, such as constitute Albunex, are susceptible to decreases in size due to diffusion and destruction by ventricular systolic pressure and acoustic pressure during fundamen-tal ultrasound imaging. 17,18 Signi cantly greater duration of contrast has been achieved with per uoropropane-lled albumin microspheres (Optison), 6 as well as with other microbubble preparations that contain uorocarbon gases, which have low solubility and diffusivity and are more pressure resistant. 1 9,20 Studies have shown that such agents are more effective than Albunex for improving delineation of endocardial border.…”
Section: Discussionmentioning
confidence: 99%
“…In patients with low cardiac output states, signi cant left ventricular cavity opaci cation is observed in less than 50%. 19 In other patients, the agent has a short effective half-life, generally persisting for several cardiac cycles only, with loss of contrast effect in the left ventricle during systole. 19 Studies indicate that Albunex is extremely pressure sensitive; high left ventricular pressures during systole result in either bubble destruction, bubble compression, or an accelerated rate of air diffusion with loss of contrast effect.…”
Section: Albunexmentioning
confidence: 99%
“…Für jedes dieser Segmente wurde die Wandbewegung als normo-, hyper-, hypo-, a-, oder dyskinetisch klassifiziert (21 Für jede Schnittebene wurden jeweils 9 ml Kontrastmittellösung verwendet. Die Dosis wurde aufgrund früherer Studienergebnisse mit diesem Kontrastmittel gewählt (4,6,9,29,30). Das Kontrastmittel wurde über eine flexible Verweilkanüle (20G) in der rechten V. cubitalis mit einer Injektionsrate von 1 ml/s injiziert.…”
Section: Herzkatheteruntersuchungunclassified
“…4 Zunahme der Genauigkeit der echokardiographischen biplanen Bestimmung der Ejektionsfraktion durch die Kontrastmittelgabe im Vergleich zur biplanen linksventrikulären Kineventrikulographie Tab. 2 Reproduzierbarkeit der echokardiographischen Beurteilung der 9 Wandsegmente: Abweichungen zwischen den Untersuchern (9,11,24). In der vorliegenden Untersuchung war lediglich bei 3 Patienten die Ejektionsfraktion unter 30 %.…”
Section: Diskussionunclassified