2018
DOI: 10.1016/j.pacs.2018.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Rapid scanning wide-field clutter elimination in epi-optoacoustic imaging using comb LOVIT

Abstract: Epi-style optoacoustic (OA) imaging provides flexibility by integrating the irradiation optics and ultrasound receiver, yet clutter generated by optical absorption near the probe obscures deep OA sources. Localised vibration tagging (LOVIT) retrieves OA signal from images that are acquired with and without a preceding ultrasonic pushing beam: Radiation force leads to a phase shift of signals coming from the focal area resulting in their visibility in a difference image, whereas clutter from outside the pushing… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 56 publications
0
7
0
Order By: Relevance
“…This limits the real-time capability and has safety challenges. Recently, LOVIT has been further improved by using multiple foci [19]. Another method exploits the acoustic tissue information by inversion of a linear scatter model using plane wave US measurements [16].…”
Section: Introductionmentioning
confidence: 99%
“…This limits the real-time capability and has safety challenges. Recently, LOVIT has been further improved by using multiple foci [19]. Another method exploits the acoustic tissue information by inversion of a linear scatter model using plane wave US measurements [16].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, reflection artefacts can occur that may be mistaken for real vessel structures. While some studies have attempted to identify and remove reflection artefacts, approaches are elaborate, using additional ultrasound measurements 37,40 , tissue deformations 16 , localized vibrations using acoustic radiation force impulses 19,38 , multi-wavelength illumination 17 , or training of convolutional neural networks 41 . Nonetheless, the full range of photoacoustic mesoscopy artefacts cannot yet be automatically detected or corrected and as such, understanding the resulting limitations on the acquired data is of utmost importance to prevent misinterpretation.…”
Section: Photoacoustic Mesoscopy Shows Greater Variation During In Vi...mentioning
confidence: 99%
“…Moreover, the non-isotropic illumination from the sides of the ultrasound detector array results in inefficient light delivery to the region of interest 15 , thereby leading to limited penetration depth, particularly in specimens that exhibit high absorption. Finally, the limited view can cause in-plane or out-of-plane artefacts, reducing the clarity of the images [16][17][18][19] . In addition to these technical limitations impacting accuracy, precision-related variations in image data arise from temporal, positioning, or operator-dependent factors.…”
Section: Introductionmentioning
confidence: 99%
“…A similar approach used a gelatin-cellulose phantom but quantified clutter reduction using target SBR. 84 While not all studies quantified artifact strength or reduction efficacy, most that did compared contrast-based image quality metrics, rather than noise-based metrics.…”
Section: Current Image Quality Evaluation Practices In Photoacoustic Imagingmentioning
confidence: 99%