2018
DOI: 10.1016/j.zemedi.2018.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Range resolution and reproducibility of a dedicated phantom for proton PBS daily quality assurance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 17 publications
2
15
0
Order By: Relevance
“…For PBS, the ranges of single-layer beams should be verified. 98 When a large field is applied, a plane-parallel ionization chamber (with a high spatial resolution for distal fall off) may be used for range measurements. The chamber should be positioned in a sufficiently thick solid phantom material, such that the front plate is positioned in the distal fall-off gradient.…”
Section: A2 Rangementioning
confidence: 99%
“…For PBS, the ranges of single-layer beams should be verified. 98 When a large field is applied, a plane-parallel ionization chamber (with a high spatial resolution for distal fall off) may be used for range measurements. The chamber should be positioned in a sufficiently thick solid phantom material, such that the front plate is positioned in the distal fall-off gradient.…”
Section: A2 Rangementioning
confidence: 99%
“…Lamber et al., for instance, observed that their daily beam range varied to within 0.5 mm using the Sun Nuclear Daily QA3. Placidi et al . and Ding et al., also studied the daily proton beam range variation using IBA Lynx with sphinx phantom and Sun Nuclear rf‐Daily QA3, respectively, and both reported a maximum deviation in range of less than 0.5 mm.…”
Section: Resultsmentioning
confidence: 99%
“…Similar study was presented by Ding et al 7 using the rf-Daily QA3 for daily beam range check of their IBA cyclotron. Placidi et al 8 used a commercially available Sphinx phantom with the IBA Lynx to perform the daily beam range check of their cyclotron accelerator.…”
Section: Introductionmentioning
confidence: 99%
“…For daily PBS QA, it suggested tests of dose per monitor unit, range, measurement of Spread-out Bragg Peak (SOBP) width, spot delivery constancy, and x-ray/proton beam isocenter coincidence. For these tests, there are several home-made and commercial daily PBS QA devices used in the different clinics [8][9][10][11][12][13]. A new flat-panel based compact PBS daily QA prototype system, named Sphinx Compact was obtained from IBA Dosimetry (Schwarzenbruck, Germany), for a clinical beta evaluation at the University of Florida Health Proton Therapy Institute.…”
Section: Introductionmentioning
confidence: 99%
“…A new flat-panel based compact PBS daily QA prototype system, named Sphinx Compact was obtained from IBA Dosimetry (Schwarzenbruck, Germany), for a clinical beta evaluation at the University of Florida Health Proton Therapy Institute. This device, composed of a flat-panel detector combined with different plastic blocks, is more compact and modular than the Sphinx + Lynx system [12,13]. Only one correction file (for pixel sensitivity variation, background and bad pixles) has to be applied to the response of the new device.…”
Section: Introductionmentioning
confidence: 99%