Radiation damping diagnostics
Search citation statements
Paper Sections
Select...
18
6
1
0
Citation Types
0
19
0
0
Year Published
1999
2023
Publication Types
Select...
19
3
1
Relationship
0
23
Authors
Journals
Cited by 23 publications
(19 citation statements)
References 34 publications
0
19
0
0
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The optimal mixing period can be determined from an incremented array of mixing times, and the time point yielding the smallest solvent signal chosen. As mentioned, this delay may be substantially shorter than expected due to radiation damping (18, 19–22, 45). To avoid overshooting, we recommend starting with short delays, e.g., 1 ms.…”
Section: Background Of the 1d‐noesy
mentioning
confidence: 77%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The optimal mixing period can be determined from an incremented array of mixing times, and the time point yielding the smallest solvent signal chosen. As mentioned, this delay may be substantially shorter than expected due to radiation damping (18, 19–22, 45). To avoid overshooting, we recommend starting with short delays, e.g., 1 ms.…”
Section: Background Of the 1d‐noesy
mentioning
confidence: 77%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…RAdiation Damping Difference SpectroscopY (RADDSY) compares relaxation after a short (0.4 ms) rectangular 90° pulse in the absence and presence of RD followed by another 90° readout pulse 32,52 . A shift of a trapezoidal crusher gradient (amplitude mT/m; duration 3 ms) yields two sequence variants: (i) (undamped reference) and (ii) (damped case).…”
Section: Methods
mentioning
confidence: 99%
“…RAdiation Damping Difference SpectroscopY (RADDSY) compares relaxation after a short (0.4 ms) rectangular 90 • pulse in the absence and presence of RD followed by another 90 • readout pulse. 32,52 A shift of a trapezoidal crusher gradient (amplitude G = 14 mT/m; duration 3 ms) yields two sequence variants: (i) 90 • -G-𝜏-90 • -ADC (undamped reference) and (ii) 90 • -𝜏-G-90 • -ADC (damped case). The ADC (analog-to-digital converter) period indicates the time of signal detection; 𝜏 is an evolution time (between 5 and 6000 ms).…”
Section: Rd During Free Precession
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…RD is most readily identified in relaxation measurements, where radiation damping greatly accelerates relaxation processes. , However, effects of RD are widespread, in part because RD also complicates pulse width nutation experiments, thereby extending effects related to miscalibrations to experiments dependent on accurate pulse widths . Previous literature , suggested that the diffusion coefficients in simple spin–echo (Figure a) based PFG-NMR experiments are distorted by RD.…”
Section: The Pfg-nmr Experiments
mentioning
confidence: 99%