2023
DOI: 10.1016/j.jceh.2022.10.001
|View full text |Cite
|
Sign up to set email alerts
|

Questioning Diagnostic Value of Serum Matrix Metalloproteinase 7 for Biliary Atresia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 21 publications
0
6
0
Order By: Relevance
“…There are currently 9 published Asian series supporting the use of serum MMP-7 level as the new gold standard diagnostic test in BA (5–13) (Table 1). The first striking feature is that published MMP-7 cut-off values vary hugely between the published studies with more than a 40-fold difference.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There are currently 9 published Asian series supporting the use of serum MMP-7 level as the new gold standard diagnostic test in BA (5–13) (Table 1). The first striking feature is that published MMP-7 cut-off values vary hugely between the published studies with more than a 40-fold difference.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, serum level of matrix metalloproteinase-7 (MMP-7) has been studied as promising biomarker to accurately distinguish BA from other causes of neonatal cholestasis (4)(5)(6)(7)(8)(9)(10)(11)(12)(13). A recent systematic review of the value of pre-Kasai MMP-7 serum levels in detecting BA reported a collective sensitivity and speciicity of 96% and 91%, respectively (14).…”
mentioning
confidence: 99%
“…Sakaguchi et al [ 22 ] and the review by Tang et al [ 24 ] found that serum MMP-7 is a useful marker for the diagnosis of BA. However, Karbasian et al [ 14 ] questioned the diagnostic value of MMP7 in differentiating BA from non-BA cases in the Middle Eastern population. They stated that MMP7 lacks enough specificity and lower diagnostic accuracy compared to GGT in diagnosing BA from other causes of NC.…”
Section: Discussionmentioning
confidence: 99%
“…A study in Iran found the capability of the MMP-7 to distinguish BA from the non-BA cholestasis group fell significantly short of expectations. 39 We note that this study used a different ELISA kit compared to other studies. Besides, in this study, serum samples were stored at −20°C instead of −70°C or −80°C as in other studies, which may have led to protein degradation.…”
Section: Mmp-7mentioning
confidence: 96%
“…The results of some important clinical studies on MMP-7 from 2018 to 2023 are shown in Table 1. [31][32][33][34][35][36][37][38][39][40] According to the systematic review by He et al, 31 the sensitivity, specificity, and area under the curve of MMP-7 in the diagnosis of BA were 96%, 91%, and 0.9847, respectively. It is worth noting that the studies by Jiang et al 32 and Yang et al 33 were comparable, because they used the same enzyme-linked immunosorbent assay (ELISA) kit to detect serum MMP-7 concentration, both were conducted in China, and the median ages of the patients in the BA group were similar in the two studies.…”
Section: Mmp-7mentioning
confidence: 99%