2014
DOI: 10.1007/s00340-014-5906-y
|View full text |Cite
|
Sign up to set email alerts
|

Quantum cascade laser photoacoustic detection of nitrous oxide released from soils for biofuel production

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 34 publications
1
5
0
Order By: Relevance
“…To meet such needs, the sensor needs to be sensitive (e.g., as low as 25 ppb for environmental site identification), portable, and low-cost . Several methods for detecting N 2 O are being used such as infrared laser spectroscopy using quantum cascade lasers (QCL), chromatography, and amperometry. In this review, various portable N 2 O sensors [i.e., microelectromechanical system (MEMS)-based nondispersive infrared (NDIR) adsorption, electrochemical, and chemiresistive] are evaluated and compared. Additionally, we have suggested different sensing materials [metal–organic frameworks (MOFs)] that might be able to further increase sensing performance and functionality in N 2 O detection.…”
mentioning
confidence: 99%
“…To meet such needs, the sensor needs to be sensitive (e.g., as low as 25 ppb for environmental site identification), portable, and low-cost . Several methods for detecting N 2 O are being used such as infrared laser spectroscopy using quantum cascade lasers (QCL), chromatography, and amperometry. In this review, various portable N 2 O sensors [i.e., microelectromechanical system (MEMS)-based nondispersive infrared (NDIR) adsorption, electrochemical, and chemiresistive] are evaluated and compared. Additionally, we have suggested different sensing materials [metal–organic frameworks (MOFs)] that might be able to further increase sensing performance and functionality in N 2 O detection.…”
mentioning
confidence: 99%
“…This signal is essentially baseline-free as it is influenced neither by incoherent noise (acoustic noise from outside the PA cell) nor by coherent noise, as caused by wideband window absorption. , Detection methods with QCLs and multi pass sample cells have been developed . Only a few examples on the combination of QCLs with photoacoustic spectroscopy (PAS) are described in the literature. ,,, …”
Section: Pa Detection Of N2omentioning
confidence: 99%
“…21 Only a few examples on the combination of QCLs with photoacoustic spectroscopy (PAS) are described in the literature. 16,17,22,23 In this paper, we present two new PA instruments for the detection of N 2 O emissions from wastewater treatment plants (WWTPs). The instruments were combined with a dedicated sampling system to collect gaseous emissions from WWTP reactors.…”
mentioning
confidence: 99%
“…In addition, a wide range of factors affects the rate of emission including but not limited to pH, temperature, moisture, soil composition, and microflora 5 . Currently, extensive research has been focused on fundamentally understanding the processes involved in N 2 O emissions from soil and aquatic systems, and have triggered substantial interest in the to the development of analytical strategies and methods providing reliable and accurate data 11 15 .…”
Section: Introductionmentioning
confidence: 99%
“…Among the optical sensors, the mid-infrared spectral region (MIR; 2.5–25 μm) has been widely utilized for N 2 O detection 11 , 16 , 17 utilizing IR-absorption phenomena 18 . To achieve the desired sensitivity, usually multi-pass gas cell providing extended absorption path lengths are applied.…”
Section: Introductionmentioning
confidence: 99%