Quantitative Models for Prediction of Toxic Component Concentrations in Smoke Gases from FTIR Spectra
Abstract: In this paper an overview is given of several methods for quantitative analysis of FTIR spectra. Each method has its particular advantages and disadvantages. Therefore, depending on the gas component to be analysed in smoke gas spectra, an optimal choice of method has to be made. This choice depends on several different aspects:
Search citation statements
Paper Sections
Select...
14
1
0
0
Citation Types
0
4
0
0
Year Published
1998
2023
Publication Types
Select...
12
2
1
Relationship
0
15
Authors
Journals
Cited by 15 publications
(4 citation statements)
References 21 publications
0
4
0
0
“…TLCP fibers select the relatively stable benzene ring skeleton group at about 1601 cm −1 as the reference peak, while PPTA fibers select the vibrational band of the aromatic group at 1515 cm −1 as the reference band. By comparing the normalized absorbance intensity [40], the peak shape and peak intensity of the two kinds of fiber did not change under different experimental conditions, and no new absorption peak appeared, indicating that the PPTA fibers are not affected by the hydrolysis reaction [16]; additionally, of course, there is no change in the chemical structure of the TLCP fibers. It seems that the chemical structure and the orientation structure of the crystal region of the two kinds of fibers have not changed after repeated extreme F-T experiments.…”
Section: The Atr-ftir Analysis Of Tlcp and Ppta Fibers After The F-t ...mentioning
confidence: 95%
“…TLCP fibers select the relatively stable benzene ring skeleton group at about 1601 cm −1 as the reference peak, while PPTA fibers select the vibrational band of the aromatic group at 1515 cm −1 as the reference band. By comparing the normalized absorbance intensity [40], the peak shape and peak intensity of the two kinds of fiber did not change under different experimental conditions, and no new absorption peak appeared, indicating that the PPTA fibers are not affected by the hydrolysis reaction [16]; additionally, of course, there is no change in the chemical structure of the TLCP fibers. It seems that the chemical structure and the orientation structure of the crystal region of the two kinds of fibers have not changed after repeated extreme F-T experiments.…”
Section: The Atr-ftir Analysis Of Tlcp and Ppta Fibers After The F-t ...mentioning
confidence: 95%
“…[45][46] The FTIR analyser was calibrated beforehand using a single pure gas to N 2 standards with well-known concentration to quantify 15 The FTIR analysis technique used has been validated during the SAFIR project [45][46] which constituted the basis for fire gases analysis carried out following the guidelines of the standard ISO 19702. [47][48][49][50][51][52][53]…”
Section: Cone Calorimeter Testmentioning
confidence: 99%
“…The Fourier transformed infrared (FTIR) analysis technique used has been validated during the Smoke Gas Analysis by Fourier Transform Infrared Spectroscopy (SAFIR) project 60,61 which constituted the basis for fire gases analysis carried out following the guidelines of the standard ISO 19702. [60][61][62][63][64][65][66][67][68] First, to proceed to this 'calibration' step, several spectra (each one corresponding to a gaseous standard concentration diluted in N 2 ) for each species cited above were collected using our FTIR spectrometer. To obtain mixtures with different standard concentrations in N 2 , we used a dilution bench composed of several thermal mass flowmeters with outputs connected to transport the obtained gas mixture up to the FTIR gas cell through heated lines (T = 180°C).…”
Section: Gas Analysismentioning
confidence: 99%