2018
DOI: 10.17219/acem/68901
|View full text |Cite
|
Sign up to set email alerts
|

Quality control of riboflavin-treated platelet concentrates using Mirasol® PRT system: Polish experience

Abstract: Background. The quality of platelet concentrates (PCs) is affected by preparation, storage, the type of container, and pathogen reduction technology (PRT). The Mirasol® Pathogen Reduction Technology (PRT) system (Terumo BCT Inc., Lakewood, USA), which uses riboflavin and ultraviolet (UV) light, has recently been proven effective against bacteria, viruses, parasites, and leukocytes.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
15
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(17 citation statements)
references
References 28 publications
2
15
0
Order By: Relevance
“…Alterations induced by MIRASOL are similar to those observed with INTERCEPT—increased anaerobic metabolism and subsequent acidification after treatment of buffy‐coat, 52–54,56,63,66,68 or apheresis‐derived PCs 46,48–51,55,57–59 . Metabolic changes were accompanied by morphological alterations, reductions in swirling, and altered HSR 48,52,53,55,57–60,63,64,66,68 . Moderate reductions in GPIb with the activation of GPIIb‐IIIa have been similarly reported after MIRASOL exposure, 48,52,53,55,57–60,63,64,66,68 with enhanced expression of platelet activation markers and indicators of apoptosis 46–53,55–60,63,64,66 The type of bag and cell separator used may have some impact on quality parameters 59 .…”
Section: In Vitro Quality Of Platelet Concentratesmentioning
confidence: 57%
See 3 more Smart Citations
“…Alterations induced by MIRASOL are similar to those observed with INTERCEPT—increased anaerobic metabolism and subsequent acidification after treatment of buffy‐coat, 52–54,56,63,66,68 or apheresis‐derived PCs 46,48–51,55,57–59 . Metabolic changes were accompanied by morphological alterations, reductions in swirling, and altered HSR 48,52,53,55,57–60,63,64,66,68 . Moderate reductions in GPIb with the activation of GPIIb‐IIIa have been similarly reported after MIRASOL exposure, 48,52,53,55,57–60,63,64,66,68 with enhanced expression of platelet activation markers and indicators of apoptosis 46–53,55–60,63,64,66 The type of bag and cell separator used may have some impact on quality parameters 59 .…”
Section: In Vitro Quality Of Platelet Concentratesmentioning
confidence: 57%
“…Metabolic changes were accompanied by morphological alterations, reductions in swirling, and altered HSR 48,52,53,55,57–60,63,64,66,68 . Moderate reductions in GPIb with the activation of GPIIb‐IIIa have been similarly reported after MIRASOL exposure, 48,52,53,55,57–60,63,64,66,68 with enhanced expression of platelet activation markers and indicators of apoptosis 46–53,55–60,63,64,66 The type of bag and cell separator used may have some impact on quality parameters 59 . Newer formulations of PAS may partially mitigate the effects of PRT when results are compared with those in classic PAS, 63 but overall do not have a critical effect on the in vitro quality alterations 50,53,55–58,63,64,68 …”
Section: In Vitro Quality Of Platelet Concentratesmentioning
confidence: 97%
See 2 more Smart Citations
“…Since there is no effective Jolanta Antoniewicz-Papis et al, Polish transfusion medicine treatment for TA-GvHD, the only way to protect patients at risk of this serious adverse reaction is irradiation and some methods of pathogen inactivation (i.e. Intercept and Mirasol systems) [24,25]. At present, we record sporadic use of only irradiation of RBCs and PCs.…”
Section: Irradiationmentioning
confidence: 88%