2007
DOI: 10.1120/jacmp.v8i4.2683
|View full text |Cite
|
Sign up to set email alerts
|

Quality assurance device for four‐dimensional IMRT or SBRT and respiratory gating using patient‐specific intrafraction motion kernels

Abstract: Emerging technologies such as four‐dimensional computed tomography (4D CT) and implanted beacons are expected to allow clinicians to accurately model intrafraction motion and to quantitatively estimate internal target volumes (ITVs) for radiation therapy involving moving targets. In the case of intensity‐modulated (IMRT) and stereotactic body radiation therapy (SBRT) delivery, clinicians must consider the interplay between the temporal nature of the modulation and the target motion within the ITV. A need exist… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2009
2009
2017
2017

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 13 publications
(16 citation statements)
references
References 9 publications
(16 reference statements)
0
16
0
Order By: Relevance
“…With the motion in either the X or Z direction, the SDD changes in a similar fashion as a function of the gantry angle. This is important because the motion table available for this work (MotionSim, Sun Nuclear Corp, Melbourne, FL) 9 can move the phantom only in the XY (coronal) plane.…”
Section: Iic2 Motionmentioning
confidence: 99%
See 2 more Smart Citations
“…With the motion in either the X or Z direction, the SDD changes in a similar fashion as a function of the gantry angle. This is important because the motion table available for this work (MotionSim, Sun Nuclear Corp, Melbourne, FL) 9 can move the phantom only in the XY (coronal) plane.…”
Section: Iic2 Motionmentioning
confidence: 99%
“…The table motion must be synchronized with the beam start time so that the virtual motion kernel in the software would reflect the physical one. It was accomplished by using the breath hold gating feature of the accelerator and the gating simulator of the motion table, 9 as was described by Court et al 8 The gating simulator was programmed to first produce a periodic up and down (Z) 1.5 cm motion of the reflector block to establish a pattern required to initialize the accelerator gating routine (Fig. 2).…”
Section: Iic3 Table Motion Synchronization With the Beam Startmentioning
confidence: 99%
See 1 more Smart Citation
“…The MC2 was mounted atop of the MotionSim 2D (IEC XY) computer-controlled motion stage (Sun Nuclear). 7 The motion trajectory programmed into the motion stage is shown in Fig. 1.…”
Section: B3 Motion Parametersmentioning
confidence: 99%
“…Guidelines for the delivery of stereotactic lung radiotherapy have been produced in the context of multi‐institutional randomised phase III trials 3,4 . However, to date, there is only limited literature regarding the use of patient‐specific respiratory patterns in the phantom dosimetry of stereotactic body radiotherapy (SBRT) plans 5,6 …”
Section: Introductionmentioning
confidence: 99%