Order By: Relevance
“…In general, the SSQR converter is composed of a switch Q 1 , a transformer T 1 , a resonant capacitor C r , a resistive-capacitor-diode (RCD) snubber, two diodes D 1 and D 2 , and an output filter C O . Figure 3a shows the representative schematic of a step-down (buck) SSQR converter [26]. Thanks to the quasi-resonant operation, the SSQR converter reduces the turn-on and turn-off loss from Q 1 and alleviates the reverse-recovery losses from D 1 and D 2 .…”
Section: Step-up Single-switch Quasi-resonant Converter For Cpt Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…In general, the SSQR converter is composed of a switch Q 1 , a transformer T 1 , a resonant capacitor C r , a resistive-capacitor-diode (RCD) snubber, two diodes D 1 and D 2 , and an output filter C O . Figure 3a shows the representative schematic of a step-down (buck) SSQR converter [26]. Thanks to the quasi-resonant operation, the SSQR converter reduces the turn-on and turn-off loss from Q 1 and alleviates the reverse-recovery losses from D 1 and D 2 .…”
Section: Step-up Single-switch Quasi-resonant Converter For Cpt Systemsmentioning
confidence: 99%
“…The RCD snubber is used on the primary side to suppress the high voltage spike of Q 1 caused by the leakage inductance of T 1 and the high input voltage V I N at the switch turn-off transition. Especially in [26], two expensive multi-layer ceramic capacitor (MLCC) resonant capacitors with high capacitance of 22 µF are used for C r in the secondary side, in order for low f r . Since the voltage stress of D 1 and D 2 is clamped to the output voltage V O , the SSQR converter is especially good at step-up (boost) applications.…”
Section: Step-up Single-switch Quasi-resonant Converter For Cpt Systemsmentioning
confidence: 99%
“…They are converter with more number of switches and converter with bulky transformer. To overcome the reverse recovery problem of the rectifier diodes the Leakage inductors of the transformer and resonant capacitors help to achieve ZCS [10]. However, these transformers and switches increases losses in the circuit and reduce the efficiency of the converter.…”
Section: Revision Of Resonant Converter Topologiesmentioning
confidence: 99%
“…The transformer secondary side resonance technique is proposed in [22]- [29] to achieve zero current switching (ZCS) for the diode. The ZCS for the output diode is achieved with the resonant tank in the secondary side, whereas the ZVS for switches is realized through the active clamp technique [22]- [28].…”
Section: Introductionmentioning
confidence: 99%
“…The ZCS for the output diode is achieved with the resonant tank in the secondary side, whereas the ZVS for switches is realized through the active clamp technique [22]- [28]. However, such resonant technique results in an increased current stress of power switches.…”
Section: Introductionmentioning
confidence: 99%