2008
DOI: 10.1016/j.snb.2008.08.024
|View full text |Cite
|
Sign up to set email alerts
|

Pt- and Pd-nanoclusters functionalized carbon nanotubes networked films for sub-ppm gas sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
64
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 121 publications
(66 citation statements)
references
References 37 publications
2
64
0
Order By: Relevance
“…it was reduced to 0.92 and 0.54 eV for Pd 4 /SWCNT pristine and Pd 4 /SWCNT func , respectively). A similar extent of partial charge transfer, about 0.57-0.60 eV, was observed in both cases, which can be ascribed to the electronic reorganization caused by the interaction of the SWCNT and a high work function metal such as Pd [48,49]. That is, the presence of the 4d electrons of Pd in the antibonding orbitals of the nanotube leads to an enhancement of the electron density in the nanotube, and, consequently, a smaller energy gap [50].…”
Section: Dft Calculation For Pd 4 Adsorption On the Pristine And Funcsupporting
confidence: 58%
“…it was reduced to 0.92 and 0.54 eV for Pd 4 /SWCNT pristine and Pd 4 /SWCNT func , respectively). A similar extent of partial charge transfer, about 0.57-0.60 eV, was observed in both cases, which can be ascribed to the electronic reorganization caused by the interaction of the SWCNT and a high work function metal such as Pd [48,49]. That is, the presence of the 4d electrons of Pd in the antibonding orbitals of the nanotube leads to an enhancement of the electron density in the nanotube, and, consequently, a smaller energy gap [50].…”
Section: Dft Calculation For Pd 4 Adsorption On the Pristine And Funcsupporting
confidence: 58%
“…The gas feeding rate was fixed at 500 sccm in all cases. The sensitivity of the gas sensor (S) is expressed as follows [27,28]: (1) where R 0 is the resistance due to the air and R g is the resistance measured upon exposure to the NH 3 gas. The setup of the gas sensor system is depicted in Fig.…”
Section: Measurement Of the Gas Sensitivitymentioning
confidence: 99%
“…4). The sensitivity of gas sensor is expressed by [18,19] S(%) (1) where R i is the resistance in N 2 gas and R g is the resistance measured upon exposure to NO gas molecules. The CF sample showed resistive response of only a 0.8% due to the inactive NO gas adsorption sites and because it is a nonporous material, as shown in Fig.…”
Section: Gas Sensing By Resistive Responsementioning
confidence: 99%