Providing direction improves function: Comparison of a radial pore-orientated acellular collagen scaffold to clinical alternatives in a surgically induced rabbit diaphragmatic tissue defect model

Abstract: Gore-Tex® is a widely used durable patch for repair of congenital diaphragmatic defects yet may result in complications. We compared Gore-Tex with a composite of a radial pore-orientated collagen scaffold (RP-Composite) and clinically used porcine small intestinal submucosa (SIS; Surgisis®) in a rabbit model for diaphragmatic hernia. The growing rabbit mimics the rapid rib cage growth and reherniation rates seen in children. We created and immediately repaired left hemidiaphragmatic defects in 6-week-old rabbi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(18 citation statements)
references
References 56 publications
0
13
0
Order By: Relevance
“…A similar composite scaffold with porcine SIS and radially poreoriented collagen was used to treat diaphragm defects in rabbits. 154 While a SIS scaffold failed in all rabbits, the composite scaffold only failed in 22% of animals. Furthermore, the diaphragms treated with these composite scaffolds behaved similarly to uninjured diaphragms (in terms of transdiaphragmatic pressure and compliancy) compared to a widely used Gore-Tex ® patch.…”
Section: Mimicking Skeletal Muscle Architecturementioning
confidence: 96%
See 2 more Smart Citations
“…A similar composite scaffold with porcine SIS and radially poreoriented collagen was used to treat diaphragm defects in rabbits. 154 While a SIS scaffold failed in all rabbits, the composite scaffold only failed in 22% of animals. Furthermore, the diaphragms treated with these composite scaffolds behaved similarly to uninjured diaphragms (in terms of transdiaphragmatic pressure and compliancy) compared to a widely used Gore-Tex ® patch.…”
Section: Mimicking Skeletal Muscle Architecturementioning
confidence: 96%
“…Compared to a similar scaffold with randomly aligned pores, the radially pore orientated scaffold showed increased cell infiltration and increase blood vessel migration. A similar composite scaffold with porcine SIS and radially pore‐oriented collagen was used to treat diaphragm defects in rabbits 154 . While a SIS scaffold failed in all rabbits, the composite scaffold only failed in 22% of animals.…”
Section: Biomimetic Materialsmentioning
confidence: 99%
See 1 more Smart Citation
“…Gore and Associates, Flasgstaff, AZ) usually shorten in expanded polytetrafluoroethylene (e-PTFE). This biomaterial is used in more than 80% of diaphragmatic replacements (Eastwood et al, 2018). e-PTFE is an inert porous and resistant material that it is suitable for surgery.…”
Section: Materials Used As Diaphragmatic Prosthesismentioning
confidence: 99%
“…More recently, Deprest et al compared a radial pore oriented acellular collagen scaffold to two clinical used surgical meshes (Gore-Tex and Surgisis) in a surgically induced rabbit diaphragmatic tissue defect model (Eastwood et al, 2018). They found no differences in terms of hernia recurrence but a compliance closer to that of the native diaphragm for their scaffold compared to Gore-Tex.…”
Section: Materials Used As Diaphragmatic Prosthesismentioning
confidence: 99%